Series 575

Controllable, reduced pressure zone backflow preventer. Bronze body. Flanged connections PN 16.

Go to
575010.png
575005_sez~-~page-1.png
575005_dim~-~page-1.png
575010.png
575005_sez~-~page-1.png
575005_dim~-~page-1.png
Download high resolution

Product Description

Controllable, reduced pressure zone backflow preventer. Bronze body. Flanged connections PN 16.
To be coupled with flat counterflanges EN 1092-1.
BA type.
Certified to EN 12729.

Technical data

Differential operating pressure: 14 kPa
Medium temperature range: 0–65 °C
PN (Nominal pressure): PN 10
Material: bronze

Note

Upstream of the backflow preventer is mandatory to install a strainer 577 series.

Certifications

ACS
BELGAQUA
DVGW DIN CERT
KIWA
NF
SVGW
VA1.57/19919
HY-CERT
RISE SC0933-09
PZH
KIWA UK

Drawings and specifications

Part number Connection DN
2D drawings
Download
Download
3D models
Download
Tender text
Controllable, reduced pressure zone backflow preventer. Bronze body. Flanged connections PN 16. To be coupled with flat counterflanges EN 1092-1. BA type. Certified to EN 12729. Connection: DN 50 (EN 1092-1) PN 16. Differential operating pressure: 14 kPa. Medium temperature range: 0–65 °C. PN (Nominal pressure): PN 10. DN: DN 50 (body). Material: bronze.
SCIP code
0f06b5a6-875f-4865-a523-5f0866a8bd37
2D drawings
Download
Download
3D models
Download
Tender text
Controllable, reduced pressure zone backflow preventer. Bronze body. Flanged connections PN 16. To be coupled with flat counterflanges EN 1092-1. BA type. Certified to EN 12729. Connection: DN 65 (EN 1092-1) PN 16. Differential operating pressure: 14 kPa. Medium temperature range: 0–65 °C. PN (Nominal pressure): PN 10. DN: DN 65 (body). Material: bronze.
SCIP code
3b1f5b59-6229-47e6-8920-b1a2f6cdcc3d
2D drawings
Download
Download
3D models
Download
Tender text
Controllable, reduced pressure zone backflow preventer. Bronze body. Flanged connections PN 16. To be coupled with flat counterflanges EN 1092-1. BA type. Certified to EN 12729. Connection: DN 80 (EN 1092-1) PN 16. Differential operating pressure: 14 kPa. Medium temperature range: 0–65 °C. PN (Nominal pressure): PN 10. DN: DN 80 (body). Material: bronze.
SCIP code
6d24dc78-8501-4912-9dca-f92c0373261d
2D drawings
Download
Download
3D models
Download
Tender text
Controllable, reduced pressure zone backflow preventer. Bronze body. Flanged connections PN 16. To be coupled with flat counterflanges EN 1092-1. BA type. Certified to EN 12729. Connection: DN 100 (EN 1092-1) PN 16. Differential operating pressure: 14 kPa. Medium temperature range: 0–65 °C. PN (Nominal pressure): PN 10. DN: DN 100 (body). Material: bronze.
SCIP code
ace4feca-44c2-440d-8369-fd26733fa6ee

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.