CONTECA® EASY, Direct heat meter for heating and cooling systems (*).
Product Description
Direct heat meter for heating and cooling systems (*).
Complete with:
- electronic integrator with LCD display;
- pair of temperature probes ;
- pair of weld sleeve and probe pockets;
- turbine volume meter with pulse output;
- 2 pulse inlets for DCW and DHW reading.
Can be integrated with additional configuration options, to be ordered concurrently (*).
Technical data
Communication protocol:
M-Bus on RS485
Protection class:
IP 54
Running power consumption:
1 W
Electric supply:
24 V AC
Probe/cable length:
1,9 m
Accuracy class:
3
Nominal pressure:
PN 16
Medium temperature range:
2–90 °C
Note
(*) Available configuration options:
- Cooling metering option (cod. 755810)
- MODBUS-RTU transmission option (cod. 750811)
- Flow rate scanning software option for DHW recirculation (cod. 755826)
- Couple of 8 m temperature probes (cod. 750931)
Certifications
Download
Drawings and specifications
| Part number | Connection | Permanent flow rate (Qp) | Minimum flow rate (Qi) |
|---|---|---|---|
| 750404 | G 1/2" A (ISO 228-1) M |
1,5 m³/h | 30 l/h |
|
Measure type
single nozzle
|
|||
|
2D drawings
Tender text
CALEFFI, 750404, CONTECA® EASY.
Direct heat meter for zone systems and central heating systems. The metering module is supplied complete with:
- pair of immersion temperature probes (L= 1,9 m);
- pair of Y pockets;
- turbine volume meter with pulse output;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission.
Strainer mesh located in flow pocket. Connection: G 1/2" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 1,5 m³/h. Minimum flow rate (Qi): 30 l/h. Communication protocol: M-Bus on RS485. Measure type: single nozzle.
SCIP code
ae8bda41-100f-473e-bb00-eed0672e8195
|
|||
| 750405 | G 3/4" A (ISO 228-1) M |
2,5 m³/h | 50 l/h |
|
Measure type
single nozzle
|
|||
|
2D drawings
Tender text
CALEFFI, 750405, CONTECA® EASY.
Direct heat meter for zone systems and central heating systems. The metering module is supplied complete with:
- pair of immersion temperature probes (L= 1,9 m);
- pair of Y pockets;
- turbine volume meter with pulse output;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission.
Strainer mesh located in flow pocket. Connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 2,5 m³/h. Minimum flow rate (Qi): 50 l/h. Communication protocol: M-Bus on RS485. Measure type: single nozzle.
SCIP code
e774d689-ffb5-429f-896b-6bd255ec45f4
|
|||
| 750406 | G 1" A (ISO 228-1) M |
3,5 m³/h | 70 l/h |
|
Measure type
multi-nozzle
|
|||
|
2D drawings
3D models
Tender text
CALEFFI, 750406, CONTECA® EASY.
Direct heat meter for zone systems and central heating systems. The metering module is supplied complete with:
- pair of immersion temperature probes (L= 1,9 m);
- pair of Y pockets;
- turbine volume meter with pulse output;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission.
Strainer mesh located in flow pocket. Connection: G 1" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 3,5 m³/h. Minimum flow rate (Qi): 70 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
279c6a31-17a7-408d-8ddd-215a9d114aae
|
|||
| 750407 | G 1 1/4" A (ISO 228-1) M |
6 m³/h | 120 l/h |
|
Measure type
multi-nozzle
|
|||
|
2D drawings
3D models
Tender text
CALEFFI, 750407, CONTECA® EASY.
Direct heat meter for zone systems and central heating systems. The metering module is supplied complete with:
- pair of immersion temperature probes (L= 1,9 m);
- pair of Y pockets;
- turbine volume meter with pulse output;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission.
Strainer mesh located in flow pocket. Connection: G 1 1/4" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 6 m³/h. Minimum flow rate (Qi): 120 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
0dfd96ea-3748-4a19-8202-9f70faa2cd84
|
|||
| 750408 | G 1 1/2" A (ISO 228-1) M |
10 m³/h | 200 l/h |
|
Measure type
multi-nozzle
|
|||
|
2D drawings
3D models
Tender text
CALEFFI, 750408, CONTECA® EASY.
Direct heat meter for zone systems and central heating systems. The metering module is supplied complete with:
- pair of immersion temperature probes (L= 1,9 m);
- pair of Y pockets;
- turbine volume meter with pulse output;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission.
Strainer mesh located in flow pocket. Connection: G 1 1/2" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 10 m³/h. Minimum flow rate (Qi): 200 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
6b0617e5-f153-44e9-9bf3-2deb08d90c34
|
|||
| 750409 | G 2" A (ISO 228-1) M |
15 m³/h | 300 l/h |
|
Measure type
multi-nozzle
|
|||
|
2D drawings
3D models
Tender text
CALEFFI, 750409, CONTECA® EASY.
Direct heat meter for zone systems and central heating systems. The metering module is supplied complete with:
- pair of immersion temperature probes (L= 1,9 m);
- pair of Y pockets;
- turbine volume meter with pulse output;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission.
Strainer mesh located in flow pocket. Connection: G 2" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 15 m³/h. Minimum flow rate (Qi): 300 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
94a67ed3-6528-4fcc-9f03-fec8435d3355
|
|||