Technical data

Maximum working pressure: 10 bar
Medium temperature range: -10–110 °C
Ambient temperature range: -10–55 °C
Power consumption: 6 VA
Protection class: IP 65
Supply cable length: 0,8 m
Auxiliary microswitch contact rating (230 V): 6 (2) A
△p max.: 10 bar
Operating time: 50 s
Operating time - Note: 90° rotation

Certifications

CE
ENEC13

Drawings and specifications

Part number Connection Electric supply Kv straight
Kv by-pass
2,45 m³/h
3D models
Tender text
Three-way motorised ball zone valve, for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv straight: 14,10 m³/h. Kv by-pass: 2,45 m³/h. Operating time: 50 s (90° rotation).
SCIP code
e5c28436-a177-43b1-9993-255ad54061e6
Kv by-pass
2,45 m³/h
3D models
Tender text
Three-way motorised ball zone valve, for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv straight: 14,10 m³/h. Kv by-pass: 2,45 m³/h. Operating time: 50 s (90° rotation).
SCIP code
f69d6945-632a-4798-82dc-bf64def9c665
Kv by-pass
2,50 m³/h
3D models
Tender text
Three-way motorised ball zone valve, for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv straight: 14,43 m³/h. Kv by-pass: 2,50 m³/h. Operating time: 50 s (90° rotation).
SCIP code
620fa024-6a3b-452b-90d9-152daf1f988b
Kv by-pass
2,50 m³/h
3D models
Tender text
Three-way motorised ball zone valve, for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv straight: 14,43 m³/h. Kv by-pass: 2,50 m³/h. Operating time: 50 s (90° rotation).
SCIP code
ab48e1f4-f5db-4825-81d8-b67bf32c5b92
Kv by-pass
3,60 m³/h
3D models
Tender text
Three-way motorised ball zone valve, for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv straight: 33,52 m³/h. Kv by-pass: 3,60 m³/h. Operating time: 50 s (90° rotation).
SCIP code
032ebea0-1966-4eb2-b416-5ff0004d2b62
Kv by-pass
3,60 m³/h
3D models
Tender text
Three-way motorised ball zone valve, for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv straight: 33,52 m³/h. Kv by-pass: 3,60 m³/h. Operating time: 50 s (90° rotation).
SCIP code
af28d284-fdbb-45e1-820a-b33024af799c
Kv by-pass
3,80 m³/h
3D models
Tender text
Three-way motorised ball zone valve, for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1 1/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv straight: 36,00 m³/h. Kv by-pass: 3,80 m³/h. Operating time: 50 s (90° rotation).
SCIP code
b11bb272-09d3-4ed0-a0bc-357311ccc5ed
Kv by-pass
3,80 m³/h
3D models
Tender text
Three-way motorised ball zone valve, for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1 1/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv straight: 36,00 m³/h. Kv by-pass: 3,80 m³/h. Operating time: 50 s (90° rotation).
SCIP code
9923965a-8eaa-4fbe-a0c5-bbaead590bb3

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.