Series 132

QuickSetter+™, Adjustable static balancing valve (NPT)

Go to
132531AFC.png
132531AFC.png
Download high resolution

Product Description

Adjustable static balancing valve (NPT)
Complete with:

  • Built-in flow meter for direct reading
  • Inlet check valve
  • Outlet temperature gauge

Technical data

Material: DZR low lead brass
Maximum glycol %: 50 %
Medium temperature range: 14 – 230 °F
Maximum operating pressure: 150 psi
Low Lead

Certifications

ES LOW LEAD
Buy American Act
California HSC 116875
Maryland HB372
United States S.3874
Vermont Act 193
NSF/ANSI/CAN 372

Drawings and specifications

Part number Connection Flow rate working range
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 132431AFC, Quicksetter+™. Adjustable static balancing valve (NPT) Complete with: Built-in flow meter for direct reading Inlet check valve Outlet temperature gauge connection: 1/2" NPT male, union. Maximum operating pressure: 150 psi. Medium temperature range: 14 – 230 °F. Maximum glycol %: 50 %. Flow rate working range: 0.5 – 1.8 gpm. Material: DZR low lead brass.
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 132531AFC, Quicksetter+™. Adjustable static balancing valve (NPT) Complete with: Built-in flow meter for direct reading Inlet check valve Outlet temperature gauge connection: 3/4" NPT male, union. Maximum operating pressure: 150 psi. Medium temperature range: 14 – 230 °F. Maximum glycol %: 50 %. Flow rate working range: 0.5 – 1.8 gpm. Material: DZR low lead brass.
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 132631AFC, Quicksetter+™. Adjustable static balancing valve (NPT) Complete with: Built-in flow meter for direct reading Inlet check valve Outlet temperature gauge connection: 1" NPT male, union. Maximum operating pressure: 150 psi. Medium temperature range: 14 – 230 °F. Maximum glycol %: 50 %. Flow rate working range: 0.5 – 1.8 gpm. Material: DZR low lead brass.
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 132451AFC, Quicksetter+™. Adjustable static balancing valve (NPT) Complete with: Built-in flow meter for direct reading Inlet check valve Outlet temperature gauge connection: 1/2" NPT male, union. Maximum operating pressure: 150 psi. Medium temperature range: 14 – 230 °F. Maximum glycol %: 50 %. Flow rate working range: 2.0 – 7.0 gpm. Material: DZR low lead brass.
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 132551AFC, Quicksetter+™. Adjustable static balancing valve (NPT) Complete with: Built-in flow meter for direct reading Inlet check valve Outlet temperature gauge connection: 3/4" NPT male, union. Maximum operating pressure: 150 psi. Medium temperature range: 14 – 230 °F. Maximum glycol %: 50 %. Flow rate working range: 2.0 – 7.0 gpm. Material: DZR low lead brass.
3D models
Tender text
CALEFFI, 132651AFC, Quicksetter+™. Adjustable static balancing valve (NPT) Complete with: Built-in flow meter for direct reading Inlet check valve Outlet temperature gauge connection: 1" NPT male, union. Maximum operating pressure: 150 psi. Medium temperature range: 14 – 230 °F. Maximum glycol %: 50 %. Flow rate working range: 2.0 – 7.0 gpm. Material: DZR low lead brass.

Applications

Caleffi Rep Locator
Caleffi Rep Locator