Series 568

Welded expansion vessel, for hot water systems, EC certification.

Go to
568050.png
568050_dim~-~page-1.png
568050.png
568050_dim~-~page-1.png
Download high resolution

Product Description

Welded expansion vessel, for hot water systems, EC certification.
Bladder diaphragm (replaceable for volumes from 60 to 500 l).
Conformity to EN 13831 standard.

Technical data

Maximum working pressure: 10 bar
System working temperature range: -10–70 °C
Diaphragm temperature range: -10–70 °C

Certifications

CE0045

Drawings and specifications

Part number Connection Pre-charge Volume
3D models
Tender text
Welded expansion vessel, for hot water systems, EC certification. Bladder diaphragm (replaceable for volumes from 60 to 500 l). Conformity to EN 13831 standard. Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. System working temperature range: -10–70 °C. Diaphragm temperature range: -10–70 °C. Pre-charge: 2,5 bar. Volume: 50 l.
3D models
Tender text
Welded expansion vessel, for hot water systems, EC certification. Bladder diaphragm (replaceable for volumes from 60 to 500 l). Conformity to EN 13831 standard. Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. System working temperature range: -10–70 °C. Diaphragm temperature range: -10–70 °C. Pre-charge: 2,5 bar. Volume: 60 l.
3D models
Tender text
Welded expansion vessel, for hot water systems, EC certification. Bladder diaphragm (replaceable for volumes from 60 to 500 l). Conformity to EN 13831 standard. Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. System working temperature range: -10–70 °C. Diaphragm temperature range: -10–70 °C. Pre-charge: 2,5 bar. Volume: 80 l.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Welded expansion vessel, for hot water systems, EC certification. Bladder diaphragm (replaceable for volumes from 60 to 500 l). Conformity to EN 13831 standard. Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. System working temperature range: -10–70 °C. Diaphragm temperature range: -10–70 °C. Pre-charge: 2,5 bar. Volume: 100 l.
3D models
Tender text
Welded expansion vessel, for hot water systems, EC certification. Bladder diaphragm (replaceable for volumes from 60 to 500 l). Conformity to EN 13831 standard. Connection: G 1 1/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. System working temperature range: -10–70 °C. Diaphragm temperature range: -10–70 °C. Pre-charge: 2,5 bar. Volume: 200 l.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Welded expansion vessel, for hot water systems, EC certification. Bladder diaphragm (replaceable for volumes from 60 to 500 l). Conformity to EN 13831 standard. Connection: G 1 1/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. System working temperature range: -10–70 °C. Diaphragm temperature range: -10–70 °C. Pre-charge: 2,5 bar. Volume: 300 l.
3D models
Tender text
Welded expansion vessel, for hot water systems, EC certification. Bladder diaphragm (replaceable for volumes from 60 to 500 l). Conformity to EN 13831 standard. Connection: G 1 1/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. System working temperature range: -10–70 °C. Diaphragm temperature range: -10–70 °C. Pre-charge: 2,5 bar. Volume: 400 l.
3D models
Tender text
Welded expansion vessel, for hot water systems, EC certification. Bladder diaphragm (replaceable for volumes from 60 to 500 l). Conformity to EN 13831 standard. Connection: G 1 1/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. System working temperature range: -10–70 °C. Diaphragm temperature range: -10–70 °C. Pre-charge: 2,5 bar. Volume: 500 l.

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.

DWS

Caleffi Domestic Water Sizer allows fast and correct sizing of the main components of domestic water systems.

Scroll