Series 182

Set point regulating unit pre-assembled in inspection wall box.

Go to
1825D7A2L.png
Download high resolution

Product Description

Set point regulating unit pre-assembled in inspection wall box.
Complete with:
- set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator;
- return manifold with built-in shut-off valves fitted for thermo-electric actuator;
- flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves;
- end fittings with automatic air vent and drain cock;
- safety thermostat;
- high-efficiency pump, UPM3 Auto L 25-70;
- inspection wall box, with floor supports.
Brass manifold body.

Certifications

CE

Drawings and specifications

Part number Connection Outlet connection Width
3D models
Tender text
CALEFFI, 1825C7A2L. Set point regulating unit pre-assembled in inspection wall box. Complete with: - set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator; - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves; - end fittings with automatic air vent and drain cock; - safety thermostat; - high-efficiency pump, UPM3 Auto L 25-70; - inspection wall box, with floor supports. Brass manifold body. Connection: G 3/4" A (ISO 228-1) M, Connection for Caleffi fittings. Outlet connection: G 3/4" A (ISO 228-1) M, 3 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. Width: 600 mm.
SCIP code
b4fd3711-be9d-42ef-9646-d8e5a3e45520
3D models
Tender text
CALEFFI, 1825D7A2L. Set point regulating unit pre-assembled in inspection wall box. Complete with: - set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator; - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves; - end fittings with automatic air vent and drain cock; - safety thermostat; - high-efficiency pump, UPM3 Auto L 25-70; - inspection wall box, with floor supports. Brass manifold body. Connection: G 3/4" A (ISO 228-1) M, Connection for Caleffi fittings. Outlet connection: G 3/4" A (ISO 228-1) M, 4 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. Width: 600 mm.
SCIP code
49578922-27bb-47a4-8a0d-06c8fd0c20a7
3D models
Tender text
CALEFFI, 1825E7A2L. Set point regulating unit pre-assembled in inspection wall box. Complete with: - set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator; - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves; - end fittings with automatic air vent and drain cock; - safety thermostat; - high-efficiency pump, UPM3 Auto L 25-70; - inspection wall box, with floor supports. Brass manifold body. Connection: G 3/4" A (ISO 228-1) M, Connection for Caleffi fittings. Outlet connection: G 3/4" A (ISO 228-1) M, 5 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. Width: 600 mm.
SCIP code
5c9d22d5-ea09-4e09-aa6e-1d6020e076e0
3D models
Tender text
CALEFFI, 1825F7A2L. Set point regulating unit pre-assembled in inspection wall box. Complete with: - set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator; - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves; - end fittings with automatic air vent and drain cock; - safety thermostat; - high-efficiency pump, UPM3 Auto L 25-70; - inspection wall box, with floor supports. Brass manifold body. Connection: G 3/4" A (ISO 228-1) M, Connection for Caleffi fittings. Outlet connection: G 3/4" A (ISO 228-1) M, 6 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. Width: 800 mm.
SCIP code
b4d0c443-2b2a-4d77-8546-5389bcd39771
3D models
Tender text
CALEFFI, 1825G7A2L. Set point regulating unit pre-assembled in inspection wall box. Complete with: - set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator; - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves; - end fittings with automatic air vent and drain cock; - safety thermostat; - high-efficiency pump, UPM3 Auto L 25-70; - inspection wall box, with floor supports. Brass manifold body. Connection: G 3/4" A (ISO 228-1) M, Connection for Caleffi fittings. Outlet connection: G 3/4" A (ISO 228-1) M, 7 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. Width: 800 mm.
SCIP code
182431d4-b347-4960-beed-94343e588006
3D models
Tender text
CALEFFI, 1825H7A2L. Set point regulating unit pre-assembled in inspection wall box. Complete with: - set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator; - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves; - end fittings with automatic air vent and drain cock; - safety thermostat; - high-efficiency pump, UPM3 Auto L 25-70; - inspection wall box, with floor supports. Brass manifold body. Connection: G 3/4" A (ISO 228-1) M, Connection for Caleffi fittings. Outlet connection: G 3/4" A (ISO 228-1) M, 8 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. Width: 800 mm.
SCIP code
8cc92981-0090-4776-b0e4-5051c3daf4ae
3D models
Tender text
CALEFFI, 1825I7A2L. Set point regulating unit pre-assembled in inspection wall box. Complete with: - set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator; - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves; - end fittings with automatic air vent and drain cock; - safety thermostat; - high-efficiency pump, UPM3 Auto L 25-70; - inspection wall box, with floor supports. Brass manifold body. Connection: G 3/4" A (ISO 228-1) M, Connection for Caleffi fittings. Outlet connection: G 3/4" A (ISO 228-1) M, 9 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. Width: 800 mm.
SCIP code
dc9ec90c-ac7f-4baf-8515-1708504d75d4
3D models
Tender text
CALEFFI, 1825L7A2L. Set point regulating unit pre-assembled in inspection wall box. Complete with: - set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator; - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves; - end fittings with automatic air vent and drain cock; - safety thermostat; - high-efficiency pump, UPM3 Auto L 25-70; - inspection wall box, with floor supports. Brass manifold body. Connection: G 3/4" A (ISO 228-1) M, Connection for Caleffi fittings. Outlet connection: G 3/4" A (ISO 228-1) M, 10 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. Width: 1000 mm.
SCIP code
7c54dc27-9f42-4481-8ae6-3364814ba6fc
3D models
Tender text
CALEFFI, 1825M7A2L. Set point regulating unit pre-assembled in inspection wall box. Complete with: - set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator; - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves; - end fittings with automatic air vent and drain cock; - safety thermostat; - high-efficiency pump, UPM3 Auto L 25-70; - inspection wall box, with floor supports. Brass manifold body. Connection: G 3/4" A (ISO 228-1) M, Connection for Caleffi fittings. Outlet connection: G 3/4" A (ISO 228-1) M, 11 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. Width: 1000 mm.
SCIP code
207c34ce-27b1-42ec-b58c-2f1c43edc736
3D models
Tender text
CALEFFI, 1825N7A2L. Set point regulating unit pre-assembled in inspection wall box. Complete with: - set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator; - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves; - end fittings with automatic air vent and drain cock; - safety thermostat; - high-efficiency pump, UPM3 Auto L 25-70; - inspection wall box, with floor supports. Brass manifold body. Connection: G 3/4" A (ISO 228-1) M, Connection for Caleffi fittings. Outlet connection: G 3/4" A (ISO 228-1) M, 12 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. Width: 1000 mm.
SCIP code
63b50cb0-cae3-4986-8061-daec9cf9684c
3D models
Tender text
CALEFFI, 1825O7A2L. Set point regulating unit pre-assembled in inspection wall box. Complete with: - set point thermostatic regulating unit,- return manifold with built-in shut-off valves fitted for thermo-electric actuator; - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold complete with flow meters with 0–5 l/m scale and flow rate balancing valves; - end fittings with automatic air vent and drain cock; - safety thermostat; - high-efficiency pump, UPM3 Auto L 25-70; - inspection wall box, with floor supports. Brass manifold body. Connection: G 3/4" A (ISO 228-1) M, Connection for Caleffi fittings. Outlet connection: G 3/4" A (ISO 228-1) M, 13 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. Width: 1000 mm.
SCIP code
9227eb13-90fa-41c5-8669-b4ad6308515d

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.