Technical data

Measure type: woltmann
Communication protocol: M-Bus on RS485
Protection class: IP 54
Running power consumption: 1 W
Electric supply: 24 V AC
Probe/cable length: 1,9 m
Accuracy class: 3
Nominal pressure: PN 16
Medium temperature range: 2–90 °C

Note

(*) Available configuration options:
- Cooling metering option (cod. 755810)
- MODBUS-RTU transmission option (cod. 750811)
- Flow rate scanning software option for DHW recirculation (cod. 755826)
- Couple of 8 m temperature probes (cod. 750931)

Certifications

CE
MI004

Drawings and specifications

Part number Connection Permanent flow rate (Qp) Minimum flow rate (Qi)
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750410, CONTECA® EASY. Direct heat meter for heating and cooling systems (*). Complete with: - electronic integrator with LCD display; - pair of temperature probes ; - pair of weld sleeve and probe pockets; - turbine volume meter with pulse output; - 2 pulse inlets for DCW and DHW reading. Local reading via LCD display/centralised reading via BUS transmission. Connection: DN 65 (EN 1092-1) PN 16. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 25 m³/h. Minimum flow rate (Qi): 2500 l/h. Communication protocol: M-Bus on RS485. Measure type: woltmann.
SCIP code
1e73a9a0-a6a3-4ce8-a0bb-d401d3c64f86
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750411, CONTECA® EASY. Direct heat meter for heating and cooling systems (*). Complete with: - electronic integrator with LCD display; - pair of temperature probes ; - pair of weld sleeve and probe pockets; - turbine volume meter with pulse output; - 2 pulse inlets for DCW and DHW reading. Local reading via LCD display/centralised reading via BUS transmission. Connection: DN 80 (EN 1092-1) PN 16. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 32 m³/h. Minimum flow rate (Qi): 3200 l/h. Communication protocol: M-Bus on RS485. Measure type: woltmann.
SCIP code
dcbf9042-d3e4-4d4e-850f-df8741b1fe75
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750412, CONTECA® EASY. Direct heat meter for heating and cooling systems (*). Complete with: - electronic integrator with LCD display; - pair of temperature probes ; - pair of weld sleeve and probe pockets; - turbine volume meter with pulse output; - 2 pulse inlets for DCW and DHW reading. Local reading via LCD display/centralised reading via BUS transmission. Connection: DN 100 (EN 1092-1) PN 16. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 50 m³/h. Minimum flow rate (Qi): 5000 l/h. Communication protocol: M-Bus on RS485. Measure type: woltmann.
SCIP code
a888c906-cc16-4f2c-9e67-3dc4910e5281
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750413, CONTECA® EASY. Direct heat meter for heating and cooling systems (*). Complete with: - electronic integrator with LCD display; - pair of temperature probes ; - pair of weld sleeve and probe pockets; - turbine volume meter with pulse output; - 2 pulse inlets for DCW and DHW reading. Local reading via LCD display/centralised reading via BUS transmission. Connection: DN 125 (EN 1092-1) PN 16. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 80 m³/h. Minimum flow rate (Qi): 8000 l/h. Communication protocol: M-Bus on RS485. Measure type: woltmann.
SCIP code
b9cccae6-1780-4e82-8c00-0322b1c14299
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750414, CONTECA® EASY. Direct heat meter for heating and cooling systems (*). Complete with: - electronic integrator with LCD display; - pair of temperature probes ; - pair of weld sleeve and probe pockets; - turbine volume meter with pulse output; - 2 pulse inlets for DCW and DHW reading. Local reading via LCD display/centralised reading via BUS transmission. Connection: DN 150 (EN 1092-1) PN 16. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 150 m³/h. Minimum flow rate (Qi): 6000 l/h. Communication protocol: M-Bus on RS485. Measure type: woltmann.
SCIP code
25db0653-417a-44c9-bc01-92002352105c
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750415, CONTECA® EASY. Direct heat meter for heating and cooling systems (*). Complete with: - electronic integrator with LCD display; - pair of temperature probes ; - pair of weld sleeve and probe pockets; - turbine volume meter with pulse output; - 2 pulse inlets for DCW and DHW reading. Local reading via LCD display/centralised reading via BUS transmission. Connection: DN 200 (EN 1092-1) PN 16. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 250 m³/h. Minimum flow rate (Qi): 10000 l/h. Communication protocol: M-Bus on RS485. Measure type: woltmann.
SCIP code
064fc544-968d-4e6d-9374-e435ad08ef8d