CONTECA EASY ULTRA, Direct heat meter for heat interface units.
Product Description
Direct heat meter for heat interface units.
Complete with:
- pair of immersion temperature probes (L= 1,9 m);
- ultrasonic volume meter with pulse output;
- electronic integrator with LCD display.
For SATK10/20/22/30/32/40 series.
Local reading via LCD display/centralised reading via BUS transmission.
Volume meter ultrasonic. 
Technical data
                        Medium temperature range:
                        2–90 °C
                      
                                          
                        Electric supply:
                        24 V AC 
                      
                                          
                        Running power consumption:
                        1 W
                      
                                          
                        Protection class:
                        IP 54
                      
                                          
                        Probe/cable length:
                        1 m
                      
                                          
                        Nominal pressure:
                        PN 16 
                      
                                          
                        Accuracy class:
                        2
                      
                                          
                        Communication protocol:
                        M-Bus on RS485
                      
                                      Certifications
Download
Drawings and specifications
| Part number | Connection | Permanent flow rate (Qp) | |
|---|---|---|---|
| 750705K | G 1" A (ISO 228-1) M | 
                      2,5 m³/h | |
| 
             2D drawings 
                    3D models 
                    
                  Tender text 
                      
                      CALEFFI, 750705K, CONTECA EASY ULTRA.
Direct heat meter for heat interface units. Complete with:
- pair of immersion temperature probes (L= 1,9 m);
- ultrasonic volume meter with pulse output;
- electronic integrator with LCD display.
 For SATK10/20/22/30/32/40 series. 
Local reading via LCD display/centralised reading via BUS transmission.
Volume meter ultrasonic. Connection: G 1" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 2,5 m³/h. Communication protocol: M-Bus on RS485. 
                     
                  SCIP code 
                        
                          9e3dc72c-74e6-4714-9825-d1ebbdda930b
                         
                       | 
        |||