Series 850

Gas pressure closing filter regulator, double diaphragm. Threaded connections.

Gas pressure closing filter regulator, double diaphragm. Threaded connections.
Download high resolution

Product Description

Gas pressure closing filter regulator, double diaphragm. Threaded connections.
Filtering capacity: Ø ≥ 50 µm.
Regulation and closing at null flow according to UNI EN 88.
Compliance with directive ATEX (II 2G - II 2D).

Technical data

Auxiliary Microswitch: NO
Battery included: NO
Electrical Components: No
Insulation: No
Gas filtration class: G2 (according to EN 779)
Medium temperature range: -15–60 °C
Maximum upstream pressure: 500 mbar

Certifications

ATEX
CE

Drawings and specifications

Part number Connection Adjustment pressure range Actions
850004 Rp 1/2" (EN 10226-1) F
18–40 mbar
3D models
Tender text
CALEFFI, 850004. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 1/2" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 18–40 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546
850005 Rp 3/4" (EN 10226-1) F
18–40 mbar
3D models
Tender text
CALEFFI, 850005. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 3/4" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 18–40 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546
850006 Rp 1" (EN 10226-1) F
18–40 mbar
3D models
Tender text
CALEFFI, 850006. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 1" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 18–40 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546
850007 Rp 1 1/4" (EN 10226-1) F
13–23 mbar
3D models
Tender text
CALEFFI, 850007. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 1 1/4" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 13–23 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546
850008 Rp 1 1/2" (EN 10226-1) F
13–23 mbar
3D models
Tender text
CALEFFI, 850008. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 1 1/2" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 13–23 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546
850009 Rp 2" (EN 10226-1) F
13–23 mbar
3D models
Tender text
CALEFFI, 850009. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 2" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 13–23 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546

Applications

Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.