Blind single distribution manifold. Male outlet connections.
Product Description
Blind single distribution manifold. Male outlet connections.
Manifold for heating and cooling systems. 
Technical data
                        Maximum working pressure:
                        10 bar
                      
                                          
                        Medium temperature range:
                        -10–110 °C
                      
                                      Download
Drawings and specifications
| Part number | Connection 1 | Outlet connection | Outlet centre distance | 
|---|---|---|---|
| 351520 | G 3/4" (ISO 228-1) F | 23 p. 1,5 M 2 outlets | 50 mm | 
| 3D models Tender text 
                      CALEFFI, 351520.
Blind single distribution manifold. Male outlet connections.
 Manifold for heating and cooling systems. Connection 1: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm. 
                     SCIP code 
                          744887bf-1cc0-4b66-b175-6fd4849385b7
                         | |||
| 351530 | G 3/4" (ISO 228-1) F | 23 p. 1,5 M 3 outlets | 50 mm | 
| 3D models Tender text 
                      CALEFFI, 351530.
Blind single distribution manifold. Male outlet connections.
 Manifold for heating and cooling systems. Connection 1: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 3 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Outlet centre distance: 50 mm. 
                     SCIP code 
                          744887bf-1cc0-4b66-b175-6fd4849385b7
                         | |||
| 351540 | G 3/4" (ISO 228-1) F | 23 p. 1,5 M 4 outlets | 50 mm | 
| 3D models Tender text 
                      CALEFFI, 351540.
Blind single distribution manifold. Male outlet connections.
 Manifold for heating and cooling systems. Connection 1: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Outlet centre distance: 50 mm. 
                     SCIP code 
                          744887bf-1cc0-4b66-b175-6fd4849385b7
                         | |||
| 351620 | G 1" (ISO 228-1) F | 23 p. 1,5 M 2 outlets | 50 mm | 
| 3D models Tender text 
                      CALEFFI, 351620.
Blind single distribution manifold. Male outlet connections.
 Manifold for heating and cooling systems. Connection 1: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Outlet centre distance: 50 mm. 
                     SCIP code 
                          744887bf-1cc0-4b66-b175-6fd4849385b7
                         | |||
| 351630 | G 1" (ISO 228-1) F inlet | 23 p. 1,5 M 3 outlets | 50 mm | 
| 3D models Tender text 
                      CALEFFI, 351630.
Blind single distribution manifold. Male outlet connections.
 Manifold for heating and cooling systems. Connection 1: G 1" (ISO 228-1) F, inlet. Outlet connection: 23 p. 1,5 M, 3 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Outlet centre distance: 50 mm. 
                     SCIP code 
                          744887bf-1cc0-4b66-b175-6fd4849385b7
                         | |||
| 351640 | G 1" (ISO 228-1) F | 23 p. 1,5 M 4 outlets | 50 mm | 
| 3D models Tender text 
                      CALEFFI, 351640.
Blind single distribution manifold. Male outlet connections.
 Manifold for heating and cooling systems. Connection 1: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Outlet centre distance: 50 mm. 