Series 356

Cast monoblock dual distribution manifold.

Cast monoblock dual distribution manifold.
Cast monoblock dual distribution manifold.
Cast monoblock dual distribution manifold.
Cast monoblock dual distribution manifold.
Cast monoblock dual distribution manifold.
Cast monoblock dual distribution manifold.
Download high resolution

Product Description

Cast monoblock dual distribution manifold.
For heating and cooling systems.

Technical data

Outlet centre distance: 40 mm
Main centre distance: 60 mm
Medium temperature range: -10–110 °C
Maximum working pressure: 10 bar

Drawings and specifications

Part number Connection Outlet connection Actions
356502 G 3/4" (ISO 228-1) F
23 p. 1,5 M
2 outlets
3D models
Tender text
CALEFFI, 356502. Cast monoblock dual distribution manifold. For heating and cooling systems. Connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Main centre distance: 60 mm. Outlet centre distance: 40 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
356504 G 3/4" (ISO 228-1) F
23 p. 1,5 M
4 outlets
3D models
Tender text
CALEFFI, 356504. Cast monoblock dual distribution manifold. For heating and cooling systems. Connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Main centre distance: 60 mm. Outlet centre distance: 40 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
356506 G 3/4" (ISO 228-1) F
23 p. 1,5 M
6 outlets
3D models
Tender text
CALEFFI, 356506. Cast monoblock dual distribution manifold. For heating and cooling systems. Connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 6 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Main centre distance: 60 mm. Outlet centre distance: 40 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
356508 G 3/4" (ISO 228-1) F
23 p. 1,5 M
8 outlets
2D drawings
3D models
Tender text
CALEFFI, 356508. Cast monoblock dual distribution manifold. For heating and cooling systems. Connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 8 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Main centre distance: 60 mm. Outlet centre distance: 40 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
356510 G 3/4" (ISO 228-1) F
23 p. 1,5 M
10 outlets
3D models
Tender text
CALEFFI, 356510. Cast monoblock dual distribution manifold. For heating and cooling systems. Connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 10 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Main centre distance: 60 mm. Outlet centre distance: 40 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
356604 G 1" (ISO 228-1) F
23 p. 1,5 M
4 outlets
3D models
Tender text
CALEFFI, 356604. Cast monoblock dual distribution manifold. For heating and cooling systems. Connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Main centre distance: 60 mm. Outlet centre distance: 40 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
356606 G 1" (ISO 228-1) F
23 p. 1,5 M
6 outlets
3D models
Tender text
CALEFFI, 356606. Cast monoblock dual distribution manifold. For heating and cooling systems. Connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 6 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Main centre distance: 60 mm. Outlet centre distance: 40 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
356608 G 1" (ISO 228-1) F
23 p. 1,5 M
8 outlets
2D drawings
3D models
Tender text
CALEFFI, 356608. Cast monoblock dual distribution manifold. For heating and cooling systems. Connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 8 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Main centre distance: 60 mm. Outlet centre distance: 40 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
356610 G 1" (ISO 228-1) F
23 p. 1,5 M
10 outlets
3D models
Tender text
CALEFFI, 356610. Cast monoblock dual distribution manifold. For heating and cooling systems. Connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 10 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Main centre distance: 60 mm. Outlet centre distance: 40 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
356612 G 1" (ISO 228-1) F
23 p. 1,5 M
12 outlets
3D models
Tender text
CALEFFI, 356612. Cast monoblock dual distribution manifold. For heating and cooling systems. Connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5 M, 12 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: 10–110 °C. Main centre distance: 60 mm. Outlet centre distance: 40 mm.
SCIP code
09f1e146-d862-4c1c-ad2d-4ca0de727260

Applications

Pipe Sizer Caleffi