Series 5751

Controllable, reduced pressure zone backflow preventer, standard version. Flanged connections.

575105.png
Download high resolution

Product Description

Controllable, reduced pressure zone backflow preventer, standard version. Flanged connections.
To be coupled with flat counterflanges EN 1092-1.
BA type.
Upstream of the backflow preventer is mandatory to install a strainer 579 series.

Certified to EN 12729.

Technical data

Finish: coated
Material: cast iron
Nominal pressure: PN 10
Medium temperature range: 5–65 °C
Differential operating pressure: 14 kPa

Certifications

ACS
SVGW
NF
PZH

Drawings and specifications

Part number Connection Actions
575105 DN 50 (EN 1092-1) PN 10
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 575105. Controllable, reduced pressure zone backflow preventer, standard version. Flanged connections. To be coupled with flat counterflanges EN 1092-1. BA type. Upstream of the backflow preventer is mandatory to install a strainer 579 series. Certified to EN 12729. Connection: DN 50 (EN 1092-1) PN 10. Differential operating pressure: 14 kPa. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. Finish: coated. Material: cast iron.
SCIP code
CODE UNDER ANALYSIS
575106 DN 65 (EN 1092-1) PN 10
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 575106. Controllable, reduced pressure zone backflow preventer, standard version. Flanged connections. To be coupled with flat counterflanges EN 1092-1. BA type. Upstream of the backflow preventer is mandatory to install a strainer 579 series. Certified to EN 12729. Connection: DN 65 (EN 1092-1) PN 10. Differential operating pressure: 14 kPa. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. Finish: coated. Material: cast iron.
SCIP code
CODE UNDER ANALYSIS
575108 DN 80 (EN 1092-1) PN 10
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 575108. Controllable, reduced pressure zone backflow preventer, standard version. Flanged connections. To be coupled with flat counterflanges EN 1092-1. BA type. Upstream of the backflow preventer is mandatory to install a strainer 579 series. Certified to EN 12729. Connection: DN 80 (EN 1092-1) PN 10. Differential operating pressure: 14 kPa. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. Finish: coated. Material: cast iron.
SCIP code
CODE UNDER ANALYSIS
575110 DN 100 (EN 1092-1) PN 10
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 575110. Controllable, reduced pressure zone backflow preventer, standard version. Flanged connections. To be coupled with flat counterflanges EN 1092-1. BA type. Upstream of the backflow preventer is mandatory to install a strainer 579 series. Certified to EN 12729. Connection: DN 100 (EN 1092-1) PN 10. Differential operating pressure: 14 kPa. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. Finish: coated. Material: cast iron.
SCIP code
CODE UNDER ANALYSIS