Product Description

Compact recessed indirect heat interface unit with hydraulic separation.
Complete with:
- modulating control valves;
- thermal safety thermostat;
- high-efficiency pump (heating circuit);
- plate heat exchanger (DWS circuit);
- plate heat exchanger (heating circuit);
- expansion vessel 7 L;
- safety valve (setting 3 bar);
- charging unit with CB-type backflow preventer;
- suitable to CONTECA EASY cod. 750405G o 750705G heat meters.
Main electronic functions:
- DWS heat exchanger preheating;
- compensated set point regulation.

Technical data

Maximum working pressure: 16 bar
Primary inlet working temperature range: 2–85 °C
Adjustment temperature range (DHW): 42–60 °C
Electric supply: 230 V AC
Running power consumption: 80 W
Depth: 110 mm
Height: 590 mm
Width: 570 mm
Maximum DHW instantaneous production: 18 l/min
△p max.: 1,65 bar

Note

(*) It is necessary to use the shut-off valve kit code F0001495.

Certifications

CE

Drawings and specifications

Part number Note Nominal heat exchanger capacity
2D drawings
Download
Download
3D models
Download
Download
Tender text
Compact recessed indirect heat interface unit with hydraulic separation. Complete with: - modulating control valves; - thermal safety thermostat; - high-efficiency pump (heating circuit); - plate heat exchanger (DWS circuit); - plate heat exchanger (heating circuit); - expansion vessel 7 L; - safety valve (setting 3 bar); - charging unit with CB-type backflow preventer; - suitable to CONTECA EASY cod. 750405G o 750705G heat meters. Main electronic functions: - DWS heat exchanger preheating; - compensated set point regulation. Maximum working pressure: 16 bar. Primary inlet working temperature range: 2–85 °C. Adjustment temperature range (DHW): 42–60 °C. Electric supply: 230 V AC. Running power consumption: 80 W. Nominal heat exchanger capacity: 40 kW. Depth: 110 mm. Height: 590 mm. Width: 570 mm. Maximum DHW instantaneous production: 18 l/min. △p max.: 1,65 bar.
3D models
Tender text
Compact recessed indirect heat interface unit with hydraulic separation. Complete with: - modulating control valves; - thermal safety thermostat; - high-efficiency pump (heating circuit); - plate heat exchanger (DWS circuit); - plate heat exchanger (heating circuit); - expansion vessel 7 L; - safety valve (setting 3 bar); - charging unit with CB-type backflow preventer; - suitable to CONTECA EASY cod. 750405G o 750705G heat meters. Main electronic functions: - DWS heat exchanger preheating; - compensated set point regulation. Maximum working pressure: 16 bar. Primary inlet working temperature range: 2–85 °C. Adjustment temperature range (DHW): 42–60 °C. Electric supply: 230 V AC. Running power consumption: 80 W. Nominal heat exchanger capacity: 40 kW. Depth: 110 mm. Height: 590 mm. Width: 570 mm. Maximum DHW instantaneous production: 18 l/min. △p max.: 1,65 bar.
SCIP code
CODICE IN FASE DI ANALISI

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.