PLURIMOD®, Compact pre-assembled user module for heating and cooling systems (*).
Product Description
Compact pre-assembled user module for heating and cooling systems (*).
Complete with:
- strainer cartrdige with stainless steel mesh;
- suitable for AUTOFLOW cartridge or static balancing headwork;
- 2 way ball zone valve;
- thermoelectric actuator with auxiliary microswitch;
- CONTECA® EASY (24 V AC) heat meter with turbine flow meter.
For use in installations with inlet on both the left- and right-hand side of the box (factory setting with inlet left-hand side).
Can be integrated with additional configuration options, to be ordered concurrently (*).
Technical data
Note
(*) Available configuration options:
- Cooling metering option (cod. 755810);
- MODBUS-RTU transmission option (cod. 750811);
- Flow rate scanning software option for DHW recirculation (cod. 755826);
- Couple of 8 m temperature probes (cod. 750931).
Certifications
Download
Drawings and specifications
| Part number | Electric supply | ||
|---|---|---|---|
| 700815 | 230 V AC | ||
|
2D drawings
3D models
Tender text
CALEFFI, 700815, PLURIMOD®.
Compact user module with heat meter template for heating and cooling systems.
Complete with:
- strainer cartrdige with stainless steel mesh;
- suitable for AUTOFLOW cartridge or static balancing headwork;
- 2 way ball zone valve;
- thermoelectric actuator with auxiliary microswitch;
- CONTECA® EASY (24 V AC) heat meter with turbine flow meter.
For use in installations with inlet on both the left- and right-hand side of the box (factory setting with inlet left-hand side). Medium temperature range: 3–90 °C. Electric supply: 230 V AC. Nominal pressure: PN 10. Maximum recommended flow rate: 1600 l/h.
SCIP code
CODE UNDER ANALYSIS
|
|||
| 700816 | 24 V AC | ||
|
2D drawings
3D models
Tender text
CALEFFI, 700816, PLURIMOD®.
Compact user module with heat meter template for heating and cooling systems.
Complete with:
- strainer cartrdige with stainless steel mesh;
- suitable for AUTOFLOW cartridge or static balancing headwork;
- 2 way ball zone valve;
- thermoelectric actuator with auxiliary microswitch;
- CONTECA® EASY (24 V AC) heat meter with turbine flow meter.
For use in installations with inlet on both the left- and right-hand side of the box (factory setting with inlet left-hand side). Medium temperature range: 3–90 °C. Electric supply: 24 V AC. Nominal pressure: PN 10. Maximum recommended flow rate: 1600 l/h.
SCIP code
CODE UNDER ANALYSIS
|
|||