LEGIOFLOW® - Multi-function compact unit for temperature control, thermal disinfection and distribution for domestic water system
Description:
Multi-function compact unit for temperature control, thermal disinfection and distribution for domestic water system. Consisting of:
- anti-scald thermostatic mixing valve,
- automatic flushing valve for thermal disinfection with thermo-electric actuator,
- shut-off ball valve with built-in strainers and check valves,
- cold water circuit outlet kit.
Inlet connections: 3/4” M.
Outlet connections: 3/4” M with union.
Mixing valve
Dezincification resistant alloy body, chrome plated.
Max. working pressure: 10 bar.
Adjustment temperature range: 30–50 °C.
Factory setting: 43 °C.
Max. inlet temperature at primary circuit: 85 °C.
Performance to standards NF 079 doc. 8,
EN 1111 and EN 1287.
Thermo-electric actuator
Normally closed.
Supply: 230 V (AC).
Power consumption: 3 W.
Protection class: IP 44.
Cable length: 80 cm.
* Without thermo-electric actuator
Downloads
Catalogue as .pdf
Technical brochure
Technical brochure
Instruction sheet
Certifications:
Drawings:
Code |
Connections |
Kv (m³/h) mixing valve |
Kv (m³/h) flushing valve |
Pack |
Package |
600500 |
3/4" |
1,75 |
1,80 |
1 |
6 |
600501* |
3/4" |
1,75 |
1,80 |
1 |