Series 797

Wall-hanging interface unit for centralized cooling systems.

Go to
797601.png
797601_dim~-~page-1.png
797601_bol~-~page-1.png
797601.png
797601_dim~-~page-1.png
797601_bol~-~page-1.png
Download high resolution

Product Description

Wall-hanging interface unit for centralized cooling systems.
Maximum head: 4 bar.
Maximum differential pressure on secondary circuit: 3 bar.
Safety relief valve setting: 3 bar.
Expansion vessel: 5 l.
With insulation.

Technical data

Maximum working pressure: 16 bar
Medium temperature range: 3–85 °C
Electric supply: 230 V (AC)
Depth: 220 mm
Height: 800 mm
Width: 480 mm
Maximum percentage of glycol: 30 %
Medium: water, glycol solutions
△p max.: 4 bar

Drawings and specifications

Part number Nominal heat exchanger capacity
3D models
Tender text
Wall-hanging interface unit for centralized cooling systems. With insulation. Maximum head: 4 bar. Maximum differential pressure on secondary circuit: 3 bar. Safety relief valve setting: 3 bar. Expansion vessel: 5 l. Maximum working pressure: 16 bar. Medium temperature range: 3–85 °C. Electric supply: 230 V (AC). Nominal heat exchanger capacity: 3 kW. Depth: 220 mm. Height: 800 mm. Width: 480 mm. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions. △p max.: 4 bar.
SCIP code
ff27aed7-52bc-4a63-b415-32988c3e39f2
3D models
Tender text
Wall-hanging interface unit for centralized cooling systems. With insulation. Maximum head: 4 bar. Maximum differential pressure on secondary circuit: 3 bar. Safety relief valve setting: 3 bar. Expansion vessel: 5 l. Maximum working pressure: 16 bar. Medium temperature range: 3–85 °C. Electric supply: 230 V (AC). Nominal heat exchanger capacity: 8 kW. Depth: 220 mm. Height: 800 mm. Width: 480 mm. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions. △p max.: 4 bar.
SCIP code
7ae4b58f-cd93-4492-a819-378ddf6b4d08
3D models
Tender text
Wall-hanging interface unit for centralized cooling systems. With insulation. Maximum head: 4 bar. Maximum differential pressure on secondary circuit: 3 bar. Safety relief valve setting: 3 bar. Expansion vessel: 5 l. Maximum working pressure: 16 bar. Medium temperature range: 3–85 °C. Electric supply: 230 V (AC). Nominal heat exchanger capacity: 15 kW. Depth: 220 mm. Height: 800 mm. Width: 480 mm. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions. △p max.: 4 bar.
SCIP code
8bf8485c-f099-4227-9dc0-3e7cec0fc749

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.