Series SATK32

Electronic wall-hanging HIU with hydraulic separation.

Go to
SATK32103.png
SATK32103_dim~-~page-1.png
SATK32103_idr~-~page-1.png
SATK32103_bol~-~page-1.png
SATK32103_ins~-~page-1.png
SATK32103.png
SATK32103_dim~-~page-1.png
SATK32103_idr~-~page-1.png
SATK32103_bol~-~page-1.png
SATK32103_ins~-~page-1.png
Show In 3D
Download high resolution

Product Description

Electronic wall-hanging HIU with hydraulic separation.

With insulation.

Technical data

Maximum working pressure: 16 bar
Adjustment temperature range: 45–75 °C
Primary inlet working temperature range: 25-45 °C, 2–90 °C
Electric supply: 230 V (AC)
Power consumption: 80 W
Depth: 245 mm
Height: 630 mm
Width: 490 mm
△p max.: 6 bar
△p max. - Notes: primary circuit

Certifications

CE
PZH

Drawings and specifications

Part number Note Nominal heat exchanger capacity Maximum DHW instantaneous production
3D models
Download
Tender text
Electronic wall-hanging HIU with hydraulic separation. With insulation. Maximum working pressure: 16 bar. Adjustment temperature range: 45–75 °C. Primary inlet working temperature range: 25-45 °C. Electric supply: 230 V (AC). Power consumption: 80 W. Nominal heat exchanger capacity: 50 kW. Depth: 245 mm. Height: 630 mm. Width: 490 mm. Maximum DHW instantaneous production: 24 l/min. △p max.: 6 bar (primary circuit).
SCIP code
a59f2952-9b21-4ce7-93cf-06babe5f67c8
3D models
Download
Tender text
Electronic wall-hanging HIU with hydraulic separation. With insulation. Maximum working pressure: 16 bar. Adjustment temperature range: 45–75 °C. Primary inlet working temperature range: 2–90 °C. Electric supply: 230 V (AC). Power consumption: 80 W. Nominal heat exchanger capacity: 60 kW. Depth: 245 mm. Height: 630 mm. Width: 490 mm. Maximum DHW instantaneous production: 24 l/min. △p max.: 6 bar (primary circuit).
SCIP code
ba104d11-3780-4770-bc94-5451e4045253
3D models
Tender text
Electronic wall-hanging HIU with hydraulic separation. With insulation. Maximum working pressure: 16 bar. Adjustment temperature range: 45–75 °C. Primary inlet working temperature range: 2–90 °C. Electric supply: 230 V (AC). Power consumption: 80 W. Nominal heat exchanger capacity: -. Depth: 245 mm. Height: 630 mm. Width: 490 mm. Maximum DHW instantaneous production: 24 l/min. △p max.: 6 bar (primary circuit).
SCIP code
3dd098d7-a6da-456b-9b18-c3ff655032b4

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.