Series 598

Blind single distribution manifold.

Go to
598542.png
Download high resolution

Product Description

Blind single distribution manifold.
For heating and cooling systems.
Outlet female connections.

Technical data

Maximum working pressure: 10 bar
Medium temperature range: -10–110 °C
Outlet centre distance: 50 mm

Drawings and specifications

Part number Connection Connection Outlet connection
3D models
Tender text
Blind single distribution manifold. For heating and cooling systems. Outlet female connections. Connection: G 3/4" (ISO 228-1) F, inlet. Connection: G 3/4" A (ISO 228-1) M, end outlet. outlet connection: G 1/2" (ISO 228-1) F, 2 outlets. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
3D models
Tender text
Blind single distribution manifold. For heating and cooling systems. Outlet female connections. Connection: G 3/4" (ISO 228-1) F, inlet. Connection: G 3/4" A (ISO 228-1) M, end outlet. outlet connection: G 1/2" (ISO 228-1) F, 3 outlets. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
3D models
Tender text
Blind single distribution manifold. For heating and cooling systems. Outlet female connections. Connection: G 3/4" (ISO 228-1) F, inlet. Connection: G 3/4" A (ISO 228-1) M, end outlet. outlet connection: G 1/2" (ISO 228-1) F, 4 outlets. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
3D models
Tender text
Blind single distribution manifold. For heating and cooling systems. Outlet female connections. Connection: G 1" (ISO 228-1) F, inlet. Connection: G 1" A (ISO 228-1) M, end outlet. outlet connection: G 1/2" (ISO 228-1) F, 2 outlets. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
3D models
Tender text
Blind single distribution manifold. For heating and cooling systems. Outlet female connections. Connection: G 1" (ISO 228-1) F, inlet. Connection: G 1" A (ISO 228-1) M, end outlet. outlet connection: G 1/2" (ISO 228-1) F, 3 outlets. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
3D models
Tender text
Blind single distribution manifold. For heating and cooling systems. Outlet female connections. Connection: G 1" (ISO 228-1) F, inlet. Connection: G 1" A (ISO 228-1) M, end outlet. outlet connection: G 1/2" (ISO 228-1) F, 4 outlets. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.