Water meter with pulse output.
Complete with fittings.

Technical data

Nominal pressure: PN 16
Medium: domestic water
Pulse weight: 10 l/pulse

Note

* for installation with horizontal dial facing upwards or in vertical position
** for installation with dial horizontal facing upwards

Maximum extension of the volume meter/logger connection cable: 50 m.
For use with a shielded cable with the same cross-section and routed in a dedicated raceway.

Certifications

ACS
MI001

Drawings and specifications

Part number Connection Note Medium temperature range
Permanent flow rate (Domestic water circuit) (Q3)
2,5 m³/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
Water meter with pulse output. Complete with fittings. Connection: G 1/2" A (ISO 228-1) M. Medium temperature range: 0–50 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 2,5 m³/h. Pulse weight: 10 l/pulse.
SCIP code
ff4bca56-ceb1-4b95-8b63-6bd6d2725124
Permanent flow rate (Domestic water circuit) (Q3)
4,0 m³/h
2D drawings
Download
3D models
Tender text
Water meter with pulse output. Complete with fittings. Connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 0–50 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 4,0 m³/h. Pulse weight: 10 l/pulse.
SCIP code
CODICE IN FASE DI ANALISI
Permanent flow rate (Domestic water circuit) (Q3)
6,3 m³/h
3D models
Tender text
Water meter with pulse output. Complete with fittings. Connection: G 1" A (ISO 228-1) M. Medium temperature range: 0–50 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 6,3 m³/h. Pulse weight: 10 l/pulse.
SCIP code
a1cf4e75-96ec-4ffa-9456-1150fa1a5ed6
Permanent flow rate (Domestic water circuit) (Q3)
10 m³/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
Water meter with pulse output. Complete with fittings. Connection: G 1 1/4" A (ISO 228-1) M. Medium temperature range: 0–50 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 10 m³/h. Pulse weight: 10 l/pulse.
SCIP code
d53f1231-cf5d-4ef9-94f8-cdb2fa417463
Permanent flow rate (Domestic water circuit) (Q3)
16 m³/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
Volume meter with pulse output. Complete with fittings. Connection: G 1 1/2" A (ISO 228-1) M. Medium temperature range: 0–50 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 16 m³/h. Pulse weight: 10 l/pulse.
SCIP code
d9be3588-5984-4a3b-baa3-88c5c05b763b
Permanent flow rate (Domestic water circuit) (Q3)
25 m³/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
Water meter with pulse output. Complete with fittings. Connection: R 2" (EN 10226-1) M. Medium temperature range: 0–50 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 25 m³/h. Pulse weight: 10 l/pulse.
SCIP code
5a99dfbe-4dcc-4bed-8b25-9bbc7c443cc9
Permanent flow rate (Domestic water circuit) (Q3)
2,5 m³/h
3D models
Tender text
Water meter with pulse output. Complete with fittings. Connection: G 1/2" A (ISO 228-1) M. Medium temperature range: 30–90 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 2,5 m³/h. Pulse weight: 10 l/pulse.
SCIP code
ff4bca56-ceb1-4b95-8b63-6bd6d2725124
Permanent flow rate (Domestic water circuit) (Q3)
4,0 m³/h
3D models
Tender text
Water meter with pulse output. Complete with fittings. Connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 30–90 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 4,0 m³/h. Pulse weight: 10 l/pulse.
SCIP code
ff4bca56-ceb1-4b95-8b63-6bd6d2725124
Permanent flow rate (Domestic water circuit) (Q3)
6,3 m³/h
3D models
Tender text
Water meter with pulse output. Complete with fittings. Connection: G 1" A (ISO 228-1) M. Medium temperature range: 30–90 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 6,3 m³/h. Pulse weight: 10 l/pulse.
SCIP code
13311eb5-6765-416f-931d-786f8c22bcc6
Permanent flow rate (Domestic water circuit) (Q3)
10 m³/h
3D models
Tender text
Water meter with pulse output. Complete with fittings. Connection: G 1 1/4" A (ISO 228-1) M. Medium temperature range: 30–90 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 10 m³/h. Pulse weight: 10 l/pulse.
SCIP code
CODICE IN FASE DI ANALISI
Permanent flow rate (Domestic water circuit) (Q3)
16 m³/h
3D models
Tender text
Volume meter with pulse output. Complete with fittings. Connection: G 1 1/2" A (ISO 228-1) M. Medium temperature range: 30–90 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 16 m³/h. Pulse weight: 10 l/pulse.
SCIP code
CODICE IN FASE DI ANALISI
Permanent flow rate (Domestic water circuit) (Q3)
25 m³/h
3D models
Tender text
Water meter with pulse output. Complete with fittings. Connection: G 2" A (ISO 228-1) M. Medium temperature range: 30–90 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 25 m³/h. Pulse weight: 10 l/pulse.
SCIP code
CODICE IN FASE DI ANALISI