Series 665

DYNAMICAL®, Pre-assembled distribution manifold.

Go to
6656d1.png
6656D1_bol~-~page-1.png
6656D1_sez1~-~page-1.png
6656D1_dim~-~page-1.png
6656d1.png
6656D1_bol~-~page-1.png
6656D1_sez1~-~page-1.png
6656D1_dim~-~page-1.png
Download high resolution

Product Description

Pre-assembled distribution manifold.
Consisting of:
- return manifold complete with shut-off valve fitted for thermo-electric actuator;
- flow manifold complete with micrometric preregulation valves;
- end fittings consisting of air vent cocks, double radial end fittings and plug;
- pair of mounting polymer brackets with adjustable centre distance for 659 series box or wall mounting.
Dynamical cartridge.
PATENT

Technical data

Maximum working pressure: 6 bar
Medium temperature range: 5–60 °C
Outlet centre distance: 50 mm
Flow rate regulation range: 25–150 l/h

Drawings and specifications

Part number Main connection Outlet connection
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pre-assembled distribution manifold. Consisting of: - return manifold complete with shut-off valve fitted for thermo-electric actuator; - flow manifold complete with micrometric preregulation valves; - end fittings consisting of air vent cocks, double radial end fittings and plug; - pair of mounting polymer brackets with adjustable centre distance for 659 series box or wall mounting. Dynamical cartridge. main connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 4 outlets. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Outlet centre distance: 50 mm. Flow rate regulation range: 25–150 l/h.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pre-assembled distribution manifold. Consisting of: - return manifold complete with shut-off valve fitted for thermo-electric actuator; - flow manifold complete with micrometric preregulation valves; - end fittings consisting of air vent cocks, double radial end fittings and plug; - pair of mounting polymer brackets with adjustable centre distance for 659 series box or wall mounting. Dynamical cartridge. main connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 5 outlets. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Outlet centre distance: 50 mm. Flow rate regulation range: 25–150 l/h.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pre-assembled distribution manifold. Consisting of: - return manifold complete with shut-off valve fitted for thermo-electric actuator; - flow manifold complete with micrometric preregulation valves; - end fittings consisting of air vent cocks, double radial end fittings and plug; - pair of mounting polymer brackets with adjustable centre distance for 659 series box or wall mounting. Dynamical cartridge. main connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 6 outlets. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Outlet centre distance: 50 mm. Flow rate regulation range: 25–150 l/h.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pre-assembled distribution manifold. Consisting of: - return manifold complete with shut-off valve fitted for thermo-electric actuator; - flow manifold complete with micrometric preregulation valves; - end fittings consisting of air vent cocks, double radial end fittings and plug; - pair of mounting polymer brackets with adjustable centre distance for 659 series box or wall mounting. Dynamical cartridge. main connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 7 outlets. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Outlet centre distance: 50 mm. Flow rate regulation range: 25–150 l/h.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pre-assembled distribution manifold. Consisting of: - return manifold complete with shut-off valve fitted for thermo-electric actuator; - flow manifold complete with micrometric preregulation valves; - end fittings consisting of air vent cocks, double radial end fittings and plug; - pair of mounting polymer brackets with adjustable centre distance for 659 series box or wall mounting. Dynamical cartridge. main connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 8 outlets. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Outlet centre distance: 50 mm. Flow rate regulation range: 25–150 l/h.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pre-assembled distribution manifold. Consisting of: - return manifold complete with shut-off valve fitted for thermo-electric actuator; - flow manifold complete with micrometric preregulation valves; - end fittings consisting of air vent cocks, double radial end fittings and plug; - pair of mounting polymer brackets with adjustable centre distance for 659 series box or wall mounting. Dynamical cartridge. main connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 9 outlets. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Outlet centre distance: 50 mm. Flow rate regulation range: 25–150 l/h.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pre-assembled distribution manifold. Consisting of: - return manifold complete with shut-off valve fitted for thermo-electric actuator; - flow manifold complete with micrometric preregulation valves; - end fittings consisting of air vent cocks, double radial end fittings and plug; - pair of mounting polymer brackets with adjustable centre distance for 659 series box or wall mounting. Dynamical cartridge. main connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 10 outlets. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Outlet centre distance: 50 mm. Flow rate regulation range: 25–150 l/h.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pre-assembled distribution manifold. Consisting of: - return manifold complete with shut-off valve fitted for thermo-electric actuator; - flow manifold complete with micrometric preregulation valves; - end fittings consisting of air vent cocks, double radial end fittings and plug; - pair of mounting polymer brackets with adjustable centre distance for 659 series box or wall mounting. Dynamical cartridge. main connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 11 outlets. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Outlet centre distance: 50 mm. Flow rate regulation range: 25–150 l/h.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pre-assembled distribution manifold. Consisting of: - return manifold complete with shut-off valve fitted for thermo-electric actuator; - flow manifold complete with micrometric preregulation valves; - end fittings consisting of air vent cocks, double radial end fittings and plug; - pair of mounting polymer brackets with adjustable centre distance for 659 series box or wall mounting. Dynamical cartridge. main connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 12 outlets. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Outlet centre distance: 50 mm. Flow rate regulation range: 25–150 l/h.

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.