CONTECA® EASY ULTRA, Direct heat meter for heating and cooling systems (*).
Product Description
Direct heat meter for heating and cooling systems (*).
Complete with:
- electronic integrator with LCD display;
- pair of temperature probes ;
- pair of weld sleeve and probe pockets;
- ultrasonic volume meter with pulse output;
- 2 pulse inlets for DCW and DHW reading.
Can be integrated with additional configuration options, to be ordered concurrently (*).
Technical data
Note
(*) Available configuration options:
- Cooling metering option (cod. 755810)
- MODBUS-RTU transmission option (cod. 750811)
- Flow rate scanning software option for DHW recirculation (cod. 755826)
- Couple of 8 m temperature probes (cod. 750931)
Services and Connectivity
Certifications
Download
Drawings and specifications
| Part number | Connection | Permanent flow rate (Qp) | Minimum flow rate (Qi) |
|---|---|---|---|
| 750709 | DN 50 (EN 1092-1) PN 25 |
15 m³/h | 60/150 l/h |
|
2D drawings
3D models
Tender text
CALEFFI, 750709, CONTECA® EASY ULTRA.
Direct heat meter for heating and cooling systems (*).
Complete with:
- electronic integrator with LCD display;
- pair of temperature probes ;
- pair of weld sleeve and probe pockets;
- ultrasonic volume meter with pulse output;
- 2 pulse inlets for DCW and DHW reading.
Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: DN 50 (EN 1092-1) PN 25. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Accuracy class: 2. Permanent flow rate (Qp): 15 m³/h. Minimum flow rate (Qi): 60/150 l/h. Communication protocol: M-Bus on RS485.
SCIP code
fc8d5353-7683-4fda-bfe7-235be45ce57e
|
|||
| 750710 | DN 65 (EN 1092-1) PN 25 |
25 m³/h | 250 l/h |
|
2D drawings
3D models
Tender text
CALEFFI, 750710, CONTECA® EASY ULTRA.
Direct heat meter for heating and cooling systems (*).
Complete with:
- electronic integrator with LCD display;
- pair of temperature probes ;
- pair of weld sleeve and probe pockets;
- ultrasonic volume meter with pulse output;
- 2 pulse inlets for DCW and DHW reading.
Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: DN 65 (EN 1092-1) PN 25. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Accuracy class: 2. Permanent flow rate (Qp): 25 m³/h. Minimum flow rate (Qi): 250 l/h. Communication protocol: M-Bus on RS485.
SCIP code
b84f1bba-a1ac-4bf7-b444-c99408209270
|
|||
| 750711 | DN 80 (EN 1092-1) PN 25 |
40 m³/h | 400 l/h |
|
2D drawings
3D models
Tender text
CALEFFI, 750711, CONTECA® EASY ULTRA.
Direct heat meter for heating and cooling systems (*).
Complete with:
- electronic integrator with LCD display;
- pair of temperature probes ;
- pair of weld sleeve and probe pockets;
- ultrasonic volume meter with pulse output;
- 2 pulse inlets for DCW and DHW reading.
Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: DN 80 (EN 1092-1) PN 25. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Accuracy class: 2. Permanent flow rate (Qp): 40 m³/h. Minimum flow rate (Qi): 400 l/h. Communication protocol: M-Bus on RS485.
SCIP code
221505b0-2726-431b-af0c-19dba65797af
|
|||
| 750712 | DN 100 (EN 1092-1) PN 16 |
60 m³/h | 600 l/h |
|
3D models
Tender text
CALEFFI, 750712, CONTECA® EASY ULTRA.
Direct heat meter for heating and cooling systems (*).
Complete with:
- electronic integrator with LCD display;
- pair of temperature probes ;
- pair of weld sleeve and probe pockets;
- ultrasonic volume meter with pulse output;
- 2 pulse inlets for DCW and DHW reading.
Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: DN 100 (EN 1092-1) PN 16. Running power consumption: 1 W. Probe/cable length: 1,9 m. Accuracy class: 2. Permanent flow rate (Qp): 60 m³/h. Minimum flow rate (Qi): 600 l/h.
SCIP code
1a4255d8-25ad-4d96-8a95-7bf7c7c328f3
|
|||
| 750713 | DN 125 (EN 1092-1) PN 16 |
100 m³/h | 1000 l/h |
|
3D models
Tender text
CALEFFI, 750713, CONTECA® EASY ULTRA.
Direct heat meter for heating and cooling systems (*).
Complete with:
- electronic integrator with LCD display;
- pair of temperature probes ;
- pair of weld sleeve and probe pockets;
- ultrasonic volume meter with pulse output;
- 2 pulse inlets for DCW and DHW reading.
Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: DN 125 (EN 1092-1) PN 16. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Accuracy class: 2. Permanent flow rate (Qp): 100 m³/h. Minimum flow rate (Qi): 1000 l/h. Communication protocol: M-Bus on RS485.
SCIP code
07b90870-5969-40b4-a956-ce56b8074bf5
|
|||
| 750714 | DN 150 (EN 1092-1) PN 16 |
150 m³/h | 1500 l/h |
|
3D models
Tender text
CALEFFI, 750714, CONTECA® EASY ULTRA.
Direct heat meter for heating and cooling systems (*).
Complete with:
- electronic integrator with LCD display;
- pair of temperature probes ;
- pair of weld sleeve and probe pockets;
- ultrasonic volume meter with pulse output;
- 2 pulse inlets for DCW and DHW reading.
Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: DN 150 (EN 1092-1) PN 16. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Accuracy class: 2. Permanent flow rate (Qp): 150 m³/h. Minimum flow rate (Qi): 1500 l/h. Communication protocol: M-Bus on RS485.
SCIP code
b9f21ad8-fd92-483a-9e31-ba061174a306
|
|||
| 750715 | DN 200 (EN 1092-1) PN 16 |
250 m³/h | 2500 l/h |
|
3D models
Tender text
CALEFFI, 750715, CONTECA® EASY ULTRA.
Direct heat meter for heating and cooling systems (*).
Complete with:
- electronic integrator with LCD display;
- pair of temperature probes ;
- pair of weld sleeve and probe pockets;
- ultrasonic volume meter with pulse output;
- 2 pulse inlets for DCW and DHW reading.
Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: DN 200 (EN 1092-1) PN 16. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Accuracy class: 2. Permanent flow rate (Qp): 250 m³/h. Minimum flow rate (Qi): 2500 l/h. Communication protocol: M-Bus on RS485.
SCIP code
1e608329-39a5-4061-bd7c-3730018a0312
|
|||