Series 900

Female fitting.

Female fitting.
Female fitting.
Female fitting.
Female fitting.
Download high resolution

Product Description

Female fitting.
For annealed copper, hard copper, brass, mild steel and stainless steel pipes.
With double O-Ring.
Conforms to standard UNI EN 1254-4.
For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549)
Temperature range: -20 - 100 °C
For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1).
Note (*): to be used only with water and non-dangerous glycol solutions.

Technical data

Auxiliary Microswitch: NO
Battery included: NO
Electrical Components: No
Insulation: No
Medium temperature range: -25–120 °C
Maximum working pressure: 16 bar

Drawings and specifications

Part number Connection Pipe connection Note Actions
900308 G 3/8" (ISO 228-1) F
Ø 8
 -
3D models
Tender text
CALEFFI, 900308. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 3/8" (ISO 228-1) F. Pipe connection: Ø 8. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900310 G 3/8" (ISO 228-1) F
Ø 10
 -
3D models
Tender text
CALEFFI, 900310. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 3/8" (ISO 228-1) F. Pipe connection: Ø 10. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900312 G 3/8" (ISO 228-1) F
Ø 12
 -
3D models
Tender text
CALEFFI, 900312. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 3/8" (ISO 228-1) F. Pipe connection: Ø 12. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900314 G 3/8" (ISO 228-1) F
Ø 14
 -
3D models
Tender text
CALEFFI, 900314. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 3/8" (ISO 228-1) F. Pipe connection: Ø 14. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900410 G 1/2" (ISO 228-1) F
Ø 10
 -
3D models
Tender text
CALEFFI, 900410. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 1/2" (ISO 228-1) F. Pipe connection: Ø 10. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900412 G 1/2" (ISO 228-1) F
Ø 12
 -
2D drawings
3D models
Tender text
CALEFFI, 900412. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 1/2" (ISO 228-1) F. Pipe connection: Ø 12. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900414 G 1/2" (ISO 228-1) F
Ø 14
 -
3D models
Tender text
CALEFFI, 900414. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 1/2" (ISO 228-1) F. Pipe connection: Ø 14. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900415 G 1/2" (ISO 228-1) F
Ø 15
 -
3D models
Tender text
CALEFFI, 900415. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 1/2" (ISO 228-1) F. Pipe connection: Ø 15. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900416 G 1/2" (ISO 228-1) F
Ø 16
 -
2D drawings
3D models
Tender text
CALEFFI, 900416. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 1/2" (ISO 228-1) F. Pipe connection: Ø 16. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900418 G 1/2" (ISO 228-1) F
Ø 18
 -
3D models
Tender text
CALEFFI, 900418. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 1/2" (ISO 228-1) F. Pipe connection: Ø 18. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900516 G 3/4" (ISO 228-1) F
Ø 16
 -
2D drawings
3D models
Tender text
CALEFFI, 900516. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 3/4" (ISO 228-1) F. Pipe connection: Ø 16. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900518 G 3/4" (ISO 228-1) F
Ø 18
 -
2D drawings
3D models
Tender text
CALEFFI, 900518. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 3/4" (ISO 228-1) F. Pipe connection: Ø 18. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900522 G 3/4" (ISO 228-1) F
Ø 22
 -
3D models
Tender text
CALEFFI, 900522. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 3/4" (ISO 228-1) F. Pipe connection: Ø 22. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900622 G 1" (ISO 228-1) F
Ø 22
 -
2D drawings
3D models
Tender text
CALEFFI, 900622. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 1" (ISO 228-1) F. Pipe connection: Ø 22. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303
900628 G 1" (ISO 228-1) F
Ø 28
(*)
2D drawings
3D models
Tender text
CALEFFI, 900628. Female fitting. For annealed copper, hard copper, brass, mild steel and stainless steel pipes. With double O-Ring. Conforms to standard UNI EN 1254-4. For gas and fluid hydrocarbon systems (yellow O-ring conforms to standard EN 549) Temperature range: -20 - 100 °C For hydraulic and domestic water systems (Black o-ring conforms to standard EN 681.1). Note (*): to be used only with water and non-dangerous glycol solutions. Connection: G 1" (ISO 228-1) F. Pipe connection: Ø 28. Maximum working pressure: 16 bar. Medium temperature range: -25–120 °C.
SCIP code
fbe06aa5-b16f-44f8-a3a3-863638c23303

Applications

Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.