Motorised regulating unit DN 32, for heating systems.
Product Description
Motorised regulating unit DN 32, for heating systems.
Right - left convertible.
Available with three-point control signal actuator (note A) or 0(2)–10V control signal and 0–10V feedback signal (note B).
Regulation with three-way sector valve.
With insulation.
Technical data
Maximum working pressure:
10 bar
Medium temperature range:
5–100 °C
Outlet centre distance:
125 mm
Type of pump:
UPML 25-105
Note
Note A: three-point control signal actuator.
Operating time: 150 s.
Can be combined with regulators code 161010 and 1520 series.
Note B: 0(2)–10 V control signal actuator.
Feedback signal: 0–10 V.
Operating time: 75 s.
Can be combined with regulator code 161010 (for actuator electic supply use 230V / 24V transformer).
Certifications

Download
Drawings and specifications
Part number | System side connection | Boiler side connection | Note |
---|---|---|---|
167662HE2 | G 1 1/4" (ISO 228-1) F |
G 1 1/4" (ISO 228-1) F |
A |
Electric supply
230 V AC
|
Flow rate with available head 4 m w.g.
3,7 m³/h
|
||
2D drawings
3D models
Tender text
Motorised regulating unit DN 32, for heating systems.
With insulation.
Right - left convertible.
Available with three-point control signal actuator (note A) or 0(2)–10V control signal and 0–10V feedback signal (note B).
Regulation with three-way sector valve.
System side connection: G 1 1/4" (ISO 228-1) F. Boiler side connection: G 1 1/4" (ISO 228-1) F. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Electric supply: 230 V AC. Outlet centre distance: 125 mm. Flow rate with available head 4 m w.g.: 3,7 m³/h. Type of pump: UPML 25-105.
SCIP code
bec9df4f-c23a-4c61-94c6-91da0cbc99a6
|
|||
167664HE2 | G 1 1/2" A (ISO 228-1) M end outlet |
G 1 1/4" (ISO 228-1) F |
B |
Electric supply
24 V AC
|
Flow rate with available head 4 m w.g.
3,7 m³/h
|
||
3D models
Tender text
Motorised regulating unit DN 32, for heating systems.
With insulation.
Right - left convertible.
Available with three-point control signal actuator (note A) or 0(2)–10V control signal and 0–10V feedback signal (note B).
Regulation with three-way sector valve.
System side connection: G 1 1/2" A (ISO 228-1) M, end outlet. Boiler side connection: G 1 1/4" (ISO 228-1) F. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Electric supply: 24 V AC. Outlet centre distance: 125 mm. Flow rate with available head 4 m w.g.: 3,7 m³/h. Type of pump: UPML 25-105.
SCIP code
d295c0c6-2b1d-4709-8bd4-d7778484017f
|