Inertial hydraulic separator for heat pump.
Product Description
Inertial hydraulic separator for heat pump.
With insulation.
Technical data
Maximum working pressure:
4 bar
Medium temperature range:
-10–95 °C
Maximum percentage of glycol:
30 %
Medium:
glycol solutions, water
Material:
stainless steel
Download
Drawings and specifications
Part number | Connection | Maximum recommended flow rate | Volume |
---|---|---|---|
548515 | G 1" (ISO 228-1) F |
3,5 m³/h | 15 l |
2D drawings
3D models
Tender text
Wall-mounted buffer tank-hydraulic separator for heat pump.
With insulation.
Air vent top connection:
15–30 liters 1";
50 liters 1 1/4".
Drain valve bottom connection:
15–30 liters 1";
50 liters 1 1/4".
Front probe holder connection 1/4" F.
Connection: G 1" (ISO 228-1) F... Maximum working pressure: 4 bar. Medium temperature range: -10–95 °C. Maximum percentage of glycol: 30 %. Medium: glycol solutions, water. Maximum recommended flow rate: 3,5 m³/h. Volume: 15 l. Material: stainless steel.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
548520 | G 1" (ISO 228-1) F |
3,5 m³/h | 20 l |
2D drawings
3D models
Tender text
Inertial hydraulic separator for heat pump.
With insulation.
Connection: G 1" (ISO 228-1) F. Maximum working pressure: 4 bar. Medium temperature range: -10–95 °C. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions. Maximum recommended flow rate: 3,5 m³/h. Volume: 20 l. Material: stainless steel.
|
|||
548525 | G 1" (ISO 228-1) F |
3,5 m³/h | 25 l |
2D drawings
3D models
Tender text
Inertial hydraulic separator for heat pump.
With insulation.
Connection: G 1" (ISO 228-1) F... Maximum working pressure: 4 bar. Medium temperature range: -10–95 °C. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions. Maximum recommended flow rate: 3,5 m³/h. Volume: 25 l. Material: stainless steel.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
548530 | G 1" (ISO 228-1) F |
3,5 m³/h | 30 l |
2D drawings
3D models
Tender text
Inertial hydraulic separator for heat pump.
With insulation.
Connection: G 1" (ISO 228-1) F. Maximum working pressure: 4 bar. Medium temperature range: -10–95 °C. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions. Maximum recommended flow rate: 3,5 m³/h. Volume: 30 l. Material: stainless steel.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
548550 | G 1 1/4" (ISO 228-1) F |
5,5 m³/h | 50 l |
2D drawings
3D models
Tender text
Inertial hydraulic separator for heat pump.
With insulation.
Connection: G 1 1/4" (ISO 228-1) F. G 1 1/4" (ISO 228-1) F. G 1/4" (ISO 228-1) F. Maximum working pressure: 4 bar. Medium temperature range: -10–95 °C. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions. Maximum recommended flow rate: 5,5 m³/h. Volume: 50 l. Material: stainless steel.
SCIP code
CODICE IN FASE DI ANALISI
|