DYNAMICAL®, Dynamic thermostatic radiator valve fitted for thermostatic and electronic control heads, thermo-electric actuators. Angled version.
Product Description
Dynamic thermostatic radiator valve fitted for thermostatic and electronic control heads, thermo-electric actuators. Angled version.
For steel pipe.
PATENT
Technical data
Maximum working pressure:
10 bar
Medium temperature range:
5–95 °C
Finish:
chrome
Material:
brass
Certifications

Download
Drawings and specifications
Part number | Connection | Connection | Note |
---|---|---|---|
230302 | G 3/8" (ISO 228-1) F inlet, angled connection |
G 3/8" A (ISO 228-1) M end outlet, angled connection |
- |
Flow rate regulation range
20–120 l/h
|
|||
3D models
Tender text
Dynamic thermostatic radiator valve fitted for thermostatic and electronic control heads, thermo-electric actuators. Angled version.
For steel pipe. connection: G 3/8" (ISO 228-1) F, inlet, angled connection. connection: G 3/8" A (ISO 228-1) M, end outlet, angled connection. Maximum working pressure: 10 bar. Medium temperature range: 5–95 °C. Finish: chrome. Flow rate regulation range: 20–120 l/h. Material: brass.
|
|||
230312 | G 3/8" (ISO 228-1) F inlet |
G 3/8" A (ISO 228-1) M end outlet |
Low flow version |
Flow rate regulation range
10–80 l/h
|
|||
3D models
Tender text
Dynamic thermostatic radiator valve fitted for thermostatic and electronic control heads, thermo-electric actuators. Angled version.
For steel pipe. connection: G 3/8" (ISO 228-1) F, inlet. connection: G 3/8" A (ISO 228-1) M, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 5–95 °C. Finish: chrome. Flow rate regulation range: 10–80 l/h. Material: brass.
|
|||
230402 | G 1/2" (ISO 228-1) F inlet, angled connection |
G 1/2" A (ISO 228-1) M end outlet, angled connection |
- |
Flow rate regulation range
20–120 l/h
|
|||
3D models
Tender text
Dynamic thermostatic radiator valve fitted for thermostatic and electronic control heads, thermo-electric actuators. Angled version.
For steel pipe. connection: G 1/2" (ISO 228-1) F, inlet, angled connection. connection: G 1/2" A (ISO 228-1) M, end outlet, angled connection. Maximum working pressure: 10 bar. Medium temperature range: 5–95 °C. Finish: chrome. Flow rate regulation range: 20–120 l/h. Material: brass.
|
|||
230412 | G 1/2" (ISO 228-1) F inlet |
G 1/2" A (ISO 228-1) M end outlet |
Low flow version |
Flow rate regulation range
10–80 l/h
|
|||
3D models
Tender text
Dynamic thermostatic radiator valve fitted for thermostatic and electronic control heads, thermo-electric actuators. Angled version.
For steel pipe. connection: G 1/2" (ISO 228-1) F, inlet. connection: G 1/2" A (ISO 228-1) M, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 5–95 °C. Finish: chrome. Flow rate regulation range: 10–80 l/h. Material: brass.
|
|||
230500 | G 3/4" (ISO 228-1) F inlet, angled connection |
G 3/4" A (ISO 228-1) M end outlet, angled connection |
Without rubber seal |
Flow rate regulation range
20–120 l/h
|
|||
3D models
Tender text
Dynamic thermostatic radiator valve fitted for thermostatic and electronic control heads, thermo-electric actuators. Angled version.
For steel pipe. connection: G 3/4" (ISO 228-1) F, inlet, angled connection. connection: G 3/4" A (ISO 228-1) M, end outlet, angled connection. Maximum working pressure: 10 bar. Medium temperature range: 5–95 °C. Finish: chrome. Flow rate regulation range: 20–120 l/h. Material: brass.
|