Series 149

Connection and regulation kit for HVAC terminal units.

Go to
149410%20H20.png
149400%20H10_bol~-~page-1.png
149400%20H10_dim~-~page-1.png
149410%20H20.png
149400%20H10_bol~-~page-1.png
149400%20H10_dim~-~page-1.png
Download high resolution

Product Description

Connection and regulation kit for HVAC terminal units.
Complete with:
- pressure independent control valve;
- three-way shut-off valves;
- built-in by-pass;
- filter cartridge;
- drain cock.
With insulation.
PATENT PENDING

Technical data

Maximum working pressure: 25 bar
Medium temperature range: -10–120 °C
Main centre distance: 80 mm
Maximum percentage of glycol: 50 %
Medium: water, glycol solutions
Range △p: 25–400 kPa
Material: dezincification resistant brass DR

Note

Can be combined with actuators code 145013 and 6565 series thermo-electric actuators.

Drawings and specifications

Part number DN Flow rate working range
2D drawings
Download
Download
3D models
Download
Download
Tender text
Connection and regulation kit for HVAC terminal units. Complete with: - pressure independent control valve; - three-way shut-off valves; - built-in by-pass; - filter cartridge; - drain cock. Maximum working pressure: 25 bar. Medium temperature range: -10–120 °C. Main centre distance: 80 mm. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 25–400 kPa. DN: DN 15 (body). Flow rate working range: 0,02–0,20 m³/h. Material: dezincification resistant brass DR.
SCIP code
becff5e0-1de7-45cd-a502-cfb9cffe3b6e
2D drawings
Download
Download
3D models
Download
Download
Tender text
Connection and regulation kit for HVAC terminal units. Complete with: - pressure independent control valve; - three-way shut-off valves; - built-in by-pass; - filter cartridge; - drain cock. Maximum working pressure: 25 bar. Medium temperature range: -10–120 °C. Main centre distance: 80 mm. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 25–400 kPa. DN: DN 15 (body). Flow rate working range: 0,08–0,40 m³/h. Material: dezincification resistant brass DR.
SCIP code
62b5d257-90dd-441b-b444-afbf64a6a19c
2D drawings
Download
Download
3D models
Download
Download
Tender text
Connection and regulation kit for HVAC terminal units. Complete with: - pressure independent control valve; - three-way shut-off valves; - built-in by-pass; - filter cartridge; - drain cock. Maximum working pressure: 25 bar. Medium temperature range: -10–120 °C. Main centre distance: 80 mm. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 25–400 kPa. DN: DN 15 (body). Flow rate working range: 0,08–0,80 m³/h. Material: dezincification resistant brass DR.
SCIP code
ac5b6cae-9367-4043-8913-8823b8e8ba9f
2D drawings
Download
Download
3D models
Download
Download
Tender text
Connection and regulation kit for HVAC terminal units. Complete with: - pressure independent control valve; - three-way shut-off valves; - built-in by-pass; - filter cartridge; - drain cock. Maximum working pressure: 25 bar. Medium temperature range: -10–120 °C. Main centre distance: 80 mm. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 25–400 kPa. DN: DN 20 (body). Flow rate working range: 0,02–0,20 m³/h. Material: dezincification resistant brass DR.
SCIP code
3f268e5c-a56c-478f-aaf8-0e8a563e4cf2
2D drawings
Download
Download
3D models
Download
Download
Tender text
Connection and regulation kit for HVAC terminal units. Complete with: - pressure independent control valve; - three-way shut-off valves; - built-in by-pass; - filter cartridge; - drain cock. Maximum working pressure: 25 bar. Medium temperature range: -10–120 °C. Main centre distance: 80 mm. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 25–400 kPa. DN: DN 20 (body). Flow rate working range: 0,08–0,40 m³/h. Material: dezincification resistant brass DR.
SCIP code
c652cbdb-28fb-4857-b258-83f049028885
2D drawings
Download
Download
3D models
Download
Download
Tender text
Connection and regulation kit for HVAC terminal units. Complete with: - pressure independent control valve; - three-way shut-off valves; - built-in by-pass; - filter cartridge; - drain cock. Maximum working pressure: 25 bar. Medium temperature range: -10–120 °C. Main centre distance: 80 mm. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 25–400 kPa. DN: DN 20 (body). Flow rate working range: 0,08–0,80 m³/h. Material: dezincification resistant brass DR.
SCIP code
51749214-da81-46f7-a582-bb68eff9dce3
2D drawings
Download
Download
3D models
Download
Download
Tender text
Connection and regulation kit for HVAC terminal units. Complete with: - pressure independent control valve; - three-way shut-off valves; - built-in by-pass; - filter cartridge; - drain cock. Maximum working pressure: 25 bar. Medium temperature range: -10–120 °C. Main centre distance: 80 mm. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 25–400 kPa. DN: DN 20 (body). Flow rate working range: 0,12–1,20 m³/h. Material: dezincification resistant brass DR.
SCIP code
7819d8f4-918b-41c3-8621-d6c09e5e9b8a
2D drawings
Download
Download
3D models
Download
Download
Tender text
Connection and regulation kit for HVAC terminal units. Complete with: - pressure independent control valve; - three-way shut-off valves; - built-in by-pass; - filter cartridge; - drain cock. Maximum working pressure: 25 bar. Medium temperature range: -10–120 °C. Main centre distance: 80 mm. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 25–400 kPa. DN: DN 25 (body). Flow rate working range: 0,18–1,80 m³/h. Material: dezincification resistant brass DR.
SCIP code
38f62295-bf68-4ecc-b678-8d9ed5307305
2D drawings
Download
Download
3D models
Download
Download
Tender text
Connection and regulation kit for HVAC terminal units. Complete with: - pressure independent control valve; - three-way shut-off valves; - built-in by-pass; - filter cartridge; - drain cock. Maximum working pressure: 25 bar. Medium temperature range: -10–120 °C. Main centre distance: 80 mm. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 25–400 kPa. DN: DN 25 (body). Flow rate working range: 0,30–3,00 m³/h. Material: dezincification resistant brass DR.
SCIP code
309b72cd-50ab-4929-8cc6-31818ee14799
2D drawings
Download
Download
3D models
Download
Download
Tender text
Connection and regulation kit for HVAC terminal units. Complete with: - pressure independent control valve; - three-way shut-off valves; - built-in by-pass; - filter cartridge; - drain cock. Maximum working pressure: 25 bar. Medium temperature range: -10–120 °C. Main centre distance: 80 mm. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 25–400 kPa. DN: DN 25 (body). Flow rate working range: 0,37–3,70 m³/h. Material: dezincification resistant brass DR.
SCIP code
f3d00f88-e31f-4cdf-9ada-9df6895468a7

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.