Actuator for 639 series butterfly valves DN 40–DN 125.
Product Description
Actuator for 639 series butterfly valves DN 40–DN 125.
Technical data
Ambient temperature range:
-30–50 °C
Warehouse storage temperature range:
-40–80 °C
Control signal:
ON/OFF, 3 point
Protection class:
IP 54
△p max.:
3 bar
closing △p max.:
12 bar
Operating time:
90 s
Rotation:
90° rotation
Note
Compatible with microswitch code 639900.
Certifications

Download
Drawings and specifications
Part number | Note | Use | Electric supply |
---|---|---|---|
639902 | DN 40-DN 65 | 639040, 639041, 639050, 639051, 639060, 639061 | 230 V AC |
2D drawings
3D models
Tender text
Actuator for 639 series butterfly valves DN 40–DN 125. Ambient temperature range: -30–50 °C. Warehouse storage temperature range: -40–80 °C. Electric supply: 230 V AC. Control signal: ON/OFF, 3 point. Protection class: IP 54. △p max.: 3 bar. closing △p max.: 12 bar. Operating time: 90 s (90° rotation).
SCIP code
CODICE IN FASE DI ANALISI
|
|||
639912 | DN 80 | 639080, 639081 | 230 V AC |
2D drawings
3D models
Tender text
Actuator for 639 series butterfly valves DN 40–DN 125. Ambient temperature range: -30–50 °C. Warehouse storage temperature range: -40–80 °C. Electric supply: 230 V AC. Control signal: 3 point, ON/OFF. Protection class: IP 54.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
639922 | DN 100 | 639100, 639101 | 230 V AC |
2D drawings
3D models
Tender text
Actuator for 639 series butterfly valves DN 40–DN 125. Ambient temperature range: -30–50 °C. Warehouse storage temperature range: -40–80 °C. Electric supply: 230 V AC. Control signal: ON/OFF, 3 point. Protection class: IP 54.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
639932 | DN 125 | 639120, 639121 | 230 V AC |
2D drawings
3D models
Tender text
Actuator for 639 series butterfly valves DN 40–DN 125. Ambient temperature range: -30–50 °C. Warehouse storage temperature range: -40–80 °C. Electric supply: 230 V AC. Control signal: ON/OFF, 3 point. Protection class: IP 54.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
639904 | DN 40-DN 65 | 639040, 639041, 639050, 639051, 639060, 639062 | 24 V AC |
2D drawings
3D models
Tender text
Actuator for 639 series butterfly valves DN 40–DN 125. Ambient temperature range: -30–50 °C. Warehouse storage temperature range: -40–80 °C. Electric supply: 24 V AC. Control signal: 3 point, ON/OFF. Protection class: IP 54.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
639914 | DN 80 | 639080, 639081 | 24 V AC |
2D drawings
3D models
Tender text
Actuator for 639 series butterfly valves DN 40–DN 125. Ambient temperature range: -30–50 °C. Warehouse storage temperature range: -40–80 °C. Electric supply: 24 V AC. Control signal: 3 point, ON/OFF. Protection class: IP 54.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
639924 | DN 100 | 639100, 639101 | 24 V AC |
2D drawings
3D models
Tender text
Actuator for 639 series butterfly valves DN 40–DN 125. Ambient temperature range: -30–50 °C. Warehouse storage temperature range: -40–80 °C. Electric supply: 24 V AC. Control signal: 3 point, ON/OFF. Protection class: IP 54.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
639934 | DN 125 | 639120, 639121 | 24 V AC |
2D drawings
3D models
Tender text
Actuator for 639 series butterfly valves DN 40–DN 125. Ambient temperature range: -30–50 °C. Warehouse storage temperature range: -40–80 °C. Electric supply: 24 V AC. Control signal: ON/OFF, 3 point. Protection class: IP 54.
SCIP code
CODICE IN FASE DI ANALISI
|