Series 6443

Three-way motorized ball zone valve (diverting)

644350A.png
Download high resolution

Product Description

Three-way motorized ball zone valve (diverting)
Complete with:

  • 3-wire floating fail-in-place actuator
  • Auxiliary micro-switch

Connection Options:

  • Sizes: ¾ - 1”
  • Connection Types: NPT Male, Press, Sweat

Technical data

Auxiliary microswitch contact rating (24 V): 5 A
Power consumption at full capacity: 4 VA
Electric supply: 24 V AC
Medium temperature range: 20 – 230 °F

Drawings and specifications

Part number Connection Cv Actions
644350A 3/4" NPT male
union
4.5
3D models
Tender text
CALEFFI, 644350A. Three-way motorized ball zone valve (diverting) Complete with: 3-wire floating fail-in-place actuator Auxiliary micro-switch Connection Options: Sizes: ¾ - 1” Connection Types: NPT Male, Press, Sweat Connection: 3/4" NPT male, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 4.5.
644356A 3/4" Press
union
4.5
3D models
Tender text
CALEFFI, 644356A. Three-way motorized ball zone valve (diverting) Complete with: 3-wire floating fail-in-place actuator Auxiliary micro-switch Connection Options: Sizes: ¾ - 1” Connection Types: NPT Male, Press, Sweat Connection: 3/4" Press, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 4.5.
644359A 3/4" Sweat
union
4.5
3D models
Tender text
CALEFFI, 644359A. Three-way motorized ball zone valve (diverting) Complete with: 3-wire floating fail-in-place actuator Auxiliary micro-switch Connection Options: Sizes: ¾ - 1” Connection Types: NPT Male, Press, Sweat Connection: 3/4" Sweat, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 4.5.
644360A 1" NPT male
union
4.5
3D models
Tender text
CALEFFI, 644360A. Three-way motorized ball zone valve (diverting) Complete with: 3-wire floating fail-in-place actuator Auxiliary micro-switch Connection Options: Sizes: ¾ - 1” Connection Types: NPT Male, Press, Sweat Connection: 1" NPT male, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 4.5.
644366A 1" Press
union
4.5
3D models
Tender text
CALEFFI, 644366A. Three-way motorized ball zone valve (diverting) Complete with: 3-wire floating fail-in-place actuator Auxiliary micro-switch Connection Options: Sizes: ¾ - 1” Connection Types: NPT Male, Press, Sweat Connection: 1" Press, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 4.5.
644369A 1" Sweat
union
4.5
3D models
Tender text
CALEFFI, 644369A. Three-way motorized ball zone valve (diverting) Complete with: 3-wire floating fail-in-place actuator Auxiliary micro-switch Connection Options: Sizes: ¾ - 1” Connection Types: NPT Male, Press, Sweat Connection: 1" Sweat, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 4.5.
NA644300 1"
body only
4.5
3D models
Tender text
CALEFFI, NA644300. Three-way motorized ball zone valve (diverting) Complete with: 3-wire floating fail-in-place actuator Auxiliary micro-switch Connection Options: Sizes: ¾ - 1” Connection Types: NPT Male, Press, Sweat Connection: 1", body only. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 4.5.

Applications

Caleffi Rep Locator
Caleffi Rep Locator

Find your nearest Caleffi Representative