Two-way motorized ball zone valve (straight)
Product Description
Two-way motorized ball zone valve (straight)
Complete with:
- 3-wire floating fail-in-place actuator
- Auxiliary micro-switch
Connection Options:
- Sizes: ¾ - 1”
- Connection Types: NPT Male, Press, Sweat
Technical data
Auxiliary microswitch contact rating (24 V):
5 A
Power consumption at full capacity:
4 VA
Electric supply:
24 V AC
Medium temperature range:
20 – 230 °F
Download
Drawings and specifications
| Part number | Connection | Cv | Actions |
|---|---|---|---|
| 644250A | 3/4" NPT male union |
13 | |
|
3D models
Tender text
CALEFFI, 644250A.
2-way straight motorized ball zone valve
Complete with:
3-wire floating fail-in-place actuator
Micro-switch
Connection Options:
Sizes: ¾ - 1”
Connection Types: Male NPT, Press, Sweat
Connection: 3/4" NPT male, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 13.
|
|||
| 644256A | 3/4" Press union |
13 | |
|
3D models
Tender text
CALEFFI, 644256A.
2-way straight motorized ball zone valve
Complete with:
3-wire floating fail-in-place actuator
Micro-switch
Connection Options:
Sizes: ¾ - 1”
Connection Types: Male NPT, Press, Sweat
Connection: 3/4" Press, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 13.
|
|||
| 644259A | 3/4" Sweat union |
13 | |
|
3D models
Tender text
CALEFFI, 644259A.
2-way straight motorized ball zone valve
Complete with:
3-wire floating fail-in-place actuator
Micro-switch
Connection Options:
Sizes: ¾ - 1”
Connection Types: Male NPT, Press, Sweat
Connection: 3/4" Sweat, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 13.
|
|||
| 644260A | 1" NPT male union |
13 | |
|
3D models
Tender text
CALEFFI, 644260A.
2-way straight motorized ball zone valve
Complete with:
3-wire floating fail-in-place actuator
Micro-switch
Connection Options:
Sizes: ¾ - 1”
Connection Types: Male NPT, Press, Sweat
Connection: 1" NPT male, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 13.
|
|||
| 644266A | 1" Press union |
13 | |
|
3D models
Tender text
CALEFFI, 644266A.
2-way straight motorized ball zone valve
Complete with:
3-wire floating fail-in-place actuator
Micro-switch
Connection Options:
Sizes: ¾ - 1”
Connection Types: Male NPT, Press, Sweat
Connection: 1" Press, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 13.
|
|||
| 644269A | 1" Sweat union |
13 | |
|
2D drawings
3D models
Tender text
CALEFFI, 644269A.
2-way straight motorized ball zone valve
Complete with:
3-wire floating fail-in-place actuator
Micro-switch
Connection Options:
Sizes: ¾ - 1”
Connection Types: Male NPT, Press, Sweat
Connection: 1" Sweat, union. Medium temperature range: 20 – 230 °F. Electric supply: 24 V AC. Power consumption at full capacity: 4 VA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 13.
|
|||
| NA644200 | 1" body only |
13 | |
|
3D models
Tender text
CALEFFI, NA644200.
2-way straight motorized ball zone valve
3-wire floating fail-in place actuator with micro-switch