Series 6442

Motorised two-way ball zone valve.

Go to
644242.png
644242_dim~-~page-1.png
644242_sez~-~page-1.png
644242.png
644242_dim~-~page-1.png
644242_sez~-~page-1.png
Download high resolution

Product Description

Motorised two-way ball zone valve.
Complete with motor with 3-contact control.
With auxiliary microswitch.
PATENT

Technical data

Maximum working pressure: 10 bar
Medium temperature range: -5–110 °C
Ambient temperature range: 0–55 °C
Power consumption: 4 VA
Protection class: IP 44 (vertical position), IP 40 (horizontal position)
Supply cable length: 1 m
Auxiliary microswitch contact rating (230 V): 0,8 A
△p max.: 10 bar
Operating time: 40 s
Operating time - Note: 90° rotation

Certifications

CE
ENEC13
ACS

Drawings and specifications

Part number Connection Electric supply Kv
3D models
Download
Download
Tender text
Motorised two-way ball zone valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: G 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 230 V (AC). Power consumption: 4 VA. Protection class: IP 44 (vertical position), IP 40 (horizontal position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 11,1 m³/h. Operating time: 40 s (90° rotation).
SCIP code
0bc2558e-c44a-48b6-98b9-79634ebd9e82
3D models
Download
Download
Tender text
Motorised two-way ball zone valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 230 V (AC). Power consumption: 4 VA. Protection class: IP 40 (horizontal position), IP 44 (vertical position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 11,1 m³/h. Operating time: 40 s (90° rotation).
SCIP code
f30f425e-f696-4299-ae12-c5edec5938ae
3D models
Download
Download
Tender text
Motorised two-way ball zone valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 230 V (AC). Power consumption: 4 VA. Protection class: IP 44 (vertical position), IP 40 (horizontal position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 11,1 m³/h. Operating time: 40 s (90° rotation).
SCIP code
338fd096-cd05-4ea1-bb52-e8a24f512754
3D models
Tender text
Motorised two-way ball zone valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: G 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 24 V (AC). Power consumption: 4 VA. Protection class: IP 44 (vertical position), IP 40 (horizontal position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 11,1 m³/h. Operating time: 40 s (90° rotation).
SCIP code
710085db-d1f3-4ab2-8ceb-656d2fc1c409
3D models
Tender text
Motorised two-way ball zone valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 24 V (AC). Power consumption: 4 VA. Protection class: IP 40 (horizontal position), IP 44 (vertical position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 11,1 m³/h. Operating time: 40 s (90° rotation).
SCIP code
b4ea05c6-e936-4c66-a23a-c5713ad63ca6
3D models
Tender text
Motorised two-way ball zone valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 24 V (AC). Power consumption: 4 VA. Protection class: IP 44 (vertical position), IP 40 (horizontal position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 11,1 m³/h. Operating time: 40 s (90° rotation).
SCIP code
1efe33ca-8760-4245-99c3-92722f4a0c78

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.