Series 592

Modular single distribution manifold. Male outlet connections.

Modular single distribution manifold. Male outlet connections.
Download high resolution

Product Description

Modular single distribution manifold. Male outlet connections.
PTFE seal on coupling.
Note (*): without PTFE seal on coupling.

Technical data

Medium temperature range: -10–110 °C
Maximum working pressure: 10 bar

Drawings and specifications

Part number Connection 1 Connection 2 Outlet connection Actions
592525 G 3/4" (ISO 228-1) F
G 3/4" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
2 outlets
Outlet centre distance
50 mm
3D models
Tender text
CALEFFI, 592525. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 3/4" (ISO 228-1) F. Connection 2: G 3/4" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592535 G 3/4" (ISO 228-1) F
G 3/4" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
3 outlets
Outlet centre distance
50 mm
3D models
Tender text
CALEFFI, 592535. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 3/4" (ISO 228-1) F. Connection 2: G 3/4" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 3 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592545 G 3/4" (ISO 228-1) F
G 3/4" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
4 outlets
Outlet centre distance
50 mm
3D models
Tender text
CALEFFI, 592545. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 3/4" (ISO 228-1) F. Connection 2: G 3/4" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592625 G 1" (ISO 228-1) F
G 1" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
2 outlets
Outlet centre distance
50 mm
3D models
Tender text
CALEFFI, 592625. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 1" (ISO 228-1) F. Connection 2: G 1" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592635 G 1" (ISO 228-1) F
G 1" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
3 outlets
Outlet centre distance
50 mm
3D models
Tender text
CALEFFI, 592635. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 1" (ISO 228-1) F. Connection 2: G 1" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 3 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592645 G 1" (ISO 228-1) F
G 1" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
4 outlets
Outlet centre distance
50 mm
3D models
Tender text
CALEFFI, 592645. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 1" (ISO 228-1) F. Connection 2: G 1" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 50 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592626 G 1" (ISO 228-1) F
G 1" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
2 outlets
Outlet centre distance
60 mm
3D models
Tender text
CALEFFI, 592626. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 1" (ISO 228-1) F. Connection 2: G 1" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 60 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592636 G 1" (ISO 228-1) F
G 1" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
3 outlets
Outlet centre distance
60 mm
3D models
Tender text
CALEFFI, 592636. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 1" (ISO 228-1) F. Connection 2: G 1" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 3 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 60 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592646 G 1" (ISO 228-1) F
G 1" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
4 outlets
Note
-
Outlet centre distance
60 mm
3D models
Tender text
CALEFFI, 592646. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 1" (ISO 228-1) F. Connection 2: G 1" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 60 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592726 G 1 1/4" (ISO 228-1) F
G 1 1/4" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
2 outlets
Note
(*)
Outlet centre distance
60 mm
3D models
Tender text
CALEFFI, 592726. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 1 1/4" (ISO 228-1) F. Connection 2: G 1 1/4" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 60 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592736 G 1 1/4" (ISO 228-1) F
G 1 1/4" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
3 outlets
Note
(*)
Outlet centre distance
60 mm
3D models
Tender text
CALEFFI, 592736. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 1 1/4" (ISO 228-1) F. Connection 2: G 1 1/4" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 3 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 60 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592746 G 1 1/4" (ISO 228-1) F
G 1 1/4" A (ISO 228-1) M
G 1/2" A (ISO 228-1) M
4 outlets
Note
(*)
Outlet centre distance
60 mm
3D models
Tender text
CALEFFI, 592746. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 1 1/4" (ISO 228-1) F. Connection 2: G 1 1/4" A (ISO 228-1) M. Outlet connection: G 1/2" A (ISO 228-1) M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 60 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592622 G 1" (ISO 228-1) F
G 1" A (ISO 228-1) M
G 3/4" A (ISO 228-1) M
2 outlets
Outlet centre distance
60 mm
2D drawings
3D models
Tender text
CALEFFI, 592622. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 1" (ISO 228-1) F. Connection 2: G 1" A (ISO 228-1) M. Outlet connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 60 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7
592632 G 1" (ISO 228-1) F
G 1" A (ISO 228-1) M
G 3/4" A (ISO 228-1) M
3 outlets
Outlet centre distance
60 mm
2D drawings
3D models
Tender text
CALEFFI, 592632. Modular single distribution manifold. Male outlet connections. PTFE seal on coupling. Note (*): without PTFE seal on coupling. Connection 1: G 1" (ISO 228-1) F. Connection 2: G 1" A (ISO 228-1) M. Outlet connection: G 3/4" A (ISO 228-1) M, 3 outlets, Connection for Caleffi fittings. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Outlet centre distance: 60 mm.
SCIP code
744887bf-1cc0-4b66-b175-6fd4849385b7

Applications

Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.