Product Description

Adjustable thermal balancing valve with thermal disinfection capability
Complete with:

  • Low lead/ lead free brass balancing valve
  • Cavity for bypass cartridge

Model Options:
A: Valve only
B: + Isolation valves only
C: + Outlet check valve only
D: + Isolation valves & check valve
E: + Temperature gauge only
F: + Gauge & Isolation valves
G: + Gauge & check valve
H: + Gauge, Isolation valves & check valve
Connection Options:

  • Sizes: 1”, 1 ¼”
  • Connection Type: NPT Female

Accessories (sold separately):

  • Insulation jacket

Technical data

Material: DZR low lead brass
Maximum working pressure: 230 psi
Maximum inlet temperature: 195 °F
Temperature adjustment range: 95 – 150 °F
Low Lead

Drawings and specifications

Part number Connection Model Actions
116160A 1" NPT female
A
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 116160A, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability Complete with: Low lead/ lead free brass balancing valve Cavity for bypass cartridge Model Options: A: Valve only B: + Isolation valves only C: + Outlet check valve only D: + Isolation valves & check valve E: + Temperature gauge only F: + Gauge & Isolation valves G: + Gauge & check valve H: + Gauge, Isolation valves & check valve Connection Options: Sizes: 1”, 1 ¼” Connection Type: NPT Female Accessories (sold separately): Insulation jacket Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Material: DZR low lead brass.
SCIP code
CODE UNDER ANALYSIS
116170A 1 1/4" NPT female
A
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 116170A, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability Complete with: Low lead/ lead free brass balancing valve Cavity for bypass cartridge Model Options: A: Valve only B: + Isolation valves only C: + Outlet check valve only D: + Isolation valves & check valve E: + Temperature gauge only F: + Gauge & Isolation valves G: + Gauge & check valve H: + Gauge, Isolation valves & check valve Connection Options: Sizes: 1”, 1 ¼” Connection Type: NPT Female Accessories (sold separately): Insulation jacket Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Material: DZR low lead brass.
SCIP code
CODE UNDER ANALYSIS
116160A 001 1" NPT female
B
3D models
Tender text
CALEFFI, 116160A 001, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability For use in domestic hot water recirculation circuits Complete with: Cavity for bypass cartridge Optional: Outlet check valve Isolation valves Temperature gauge connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
116170A 001 1 1/4" NPT female
B
3D models
Tender text
CALEFFI, 116170A 001, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability For use in domestic hot water recirculation circuits Complete with: Cavity for bypass cartridge Optional: Outlet check valve Isolation valves Temperature gauge connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
116160AC 1" NPT female
C
3D models
Tender text
CALEFFI, 116160AC, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability Complete with: Low lead/ lead free brass balancing valve Cavity for bypass cartridge Model Options: A: Valve only B: + Isolation valves only C: + Outlet check valve only D: + Isolation valves & check valve E: + Temperature gauge only F: + Gauge & Isolation valves G: + Gauge & check valve H: + Gauge, Isolation valves & check valve Connection Options: Sizes: 1”, 1 ¼” Connection Type: NPT Female Accessories (sold separately): Insulation jacket Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: C. Material: DZR low lead brass.
116170AC 1 1/4" NPT female
C
3D models
Tender text
CALEFFI, 116170AC, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability Complete with: Low lead/ lead free brass balancing valve Cavity for bypass cartridge Model Options: A: Valve only B: + Isolation valves only C: + Outlet check valve only D: + Isolation valves & check valve E: + Temperature gauge only F: + Gauge & Isolation valves G: + Gauge & check valve H: + Gauge, Isolation valves & check valve Connection Options: Sizes: 1”, 1 ¼” Connection Type: NPT Female Accessories (sold separately): Insulation jacket Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: C. Material: DZR low lead brass.
116160AC 001 1" NPT female
D
3D models
Tender text
CALEFFI, 116160AC 001, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability For use in domestic hot water recirculation circuits Complete with: Cavity for bypass cartridge Optional: Outlet check valve Isolation valves Temperature gauge connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
116170AC 001 1 1/4" NPT female
D
3D models
Tender text
CALEFFI, 116170AC 001, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability For use in domestic hot water recirculation circuits Complete with: Cavity for bypass cartridge Optional: Outlet check valve Isolation valves Temperature gauge connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
116161A 1" NPT female
E
3D models
Tender text
CALEFFI, 116161A, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability Complete with: Low lead/ lead free brass balancing valve Cavity for bypass cartridge Model Options: A: Valve only B: + Isolation valves only C: + Outlet check valve only D: + Isolation valves & check valve E: + Temperature gauge only F: + Gauge & Isolation valves G: + Gauge & check valve H: + Gauge, Isolation valves & check valve Connection Options: Sizes: 1”, 1 ¼” Connection Type: NPT Female Accessories (sold separately): Insulation jacket Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: E. Material: DZR low lead brass.
116171A 1 1/4" NPT female
E
3D models
Tender text
CALEFFI, 116171A, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability Complete with: Low lead/ lead free brass balancing valve Cavity for bypass cartridge Model Options: A: Valve only B: + Isolation valves only C: + Outlet check valve only D: + Isolation valves & check valve E: + Temperature gauge only F: + Gauge & Isolation valves G: + Gauge & check valve H: + Gauge, Isolation valves & check valve Connection Options: Sizes: 1”, 1 ¼” Connection Type: NPT Female Accessories (sold separately): Insulation jacket Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: E. Material: DZR low lead brass.
116161A 001 1" NPT female
F
3D models
Tender text
CALEFFI, 116161A 001, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability For use in domestic hot water recirculation circuits Complete with: Cavity for bypass cartridge Optional: Outlet check valve Isolation valves Temperature gauge connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
116171A 001 1 1/4" NPT female
F
3D models
Tender text
CALEFFI, 116171A 001, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability For use in domestic hot water recirculation circuits Complete with: Cavity for bypass cartridge Optional: Outlet check valve Isolation valves Temperature gauge connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
116161AC 1" NPT female
G
3D models
Tender text
CALEFFI, 116161AC, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability Complete with: Low lead/ lead free brass balancing valve Cavity for bypass cartridge Model Options: A: Valve only B: + Isolation valves only C: + Outlet check valve only D: + Isolation valves & check valve E: + Temperature gauge only F: + Gauge & Isolation valves G: + Gauge & check valve H: + Gauge, Isolation valves & check valve Connection Options: Sizes: 1”, 1 ¼” Connection Type: NPT Female Accessories (sold separately): Insulation jacket Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: G. Material: DZR low lead brass.
116171AC 1 1/4" NPT female
G
3D models
Tender text
CALEFFI, 116171AC, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability Complete with: Low lead/ lead free brass balancing valve Cavity for bypass cartridge Model Options: A: Valve only B: + Isolation valves only C: + Outlet check valve only D: + Isolation valves & check valve E: + Temperature gauge only F: + Gauge & Isolation valves G: + Gauge & check valve H: + Gauge, Isolation valves & check valve Connection Options: Sizes: 1”, 1 ¼” Connection Type: NPT Female Accessories (sold separately): Insulation jacket Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: G. Material: DZR low lead brass.
116161AC 001 1" NPT female
H
3D models
Tender text
CALEFFI, 116161AC 001, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability For use in domestic hot water recirculation circuits Complete with: Cavity for bypass cartridge Optional: Outlet check valve Isolation valves Temperature gauge connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
116171AC 001 1 1/4" NPT female
H
3D models
Tender text
CALEFFI, 116171AC 001, ThermoSetter™. Adjustable thermal balancing valve with thermal disinfection capability For use in domestic hot water recirculation circuits Complete with: Cavity for bypass cartridge Optional: Outlet check valve Isolation valves Temperature gauge connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.

Applications

Caleffi Rep Locator
Caleffi Rep Locator

Find your nearest Caleffi Representative