ThermoSetter™, Adjustable thermal balancing valve with thermal disinfection capability
Product Description
Adjustable thermal balancing valve with thermal disinfection capability
Complete with:
- Low lead/ lead free brass balancing valve
- Cavity for bypass cartridge
Model Options:
A: Valve only
B: + Isolation valves only
C: + Outlet check valve only
D: + Isolation valves & check valve
E: + Temperature gauge only
F: + Gauge & Isolation valves
G: + Gauge & check valve
H: + Gauge, Isolation valves & check valve
Connection Options:
- Sizes: 1”, 1 ¼”
- Connection Type: NPT Female
Accessories (sold separately):
- Insulation jacket
Technical data
Material:
DZR low lead brass
Maximum working pressure:
230 psi
Maximum inlet temperature:
195 °F
Temperature adjustment range:
95 – 150 °F
Download
Drawings and specifications
| Part number | Connection | Model | Actions |
|---|---|---|---|
| 116160A | 1" NPT female |
A | |
|
2D drawings
3D models
Tender text
CALEFFI, 116160A, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
Complete with:
Low lead/ lead free brass balancing valve
Cavity for bypass cartridge
Model Options:
A: Valve only
B: + Isolation valves only
C: + Outlet check valve only
D: + Isolation valves & check valve
E: + Temperature gauge only
F: + Gauge & Isolation valves
G: + Gauge & check valve
H: + Gauge, Isolation valves & check valve
Connection Options:
Sizes: 1”, 1 ¼”
Connection Type: NPT Female
Accessories (sold separately):
Insulation jacket
Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Material: DZR low lead brass.
SCIP code
CODE UNDER ANALYSIS
|
|||
| 116170A | 1 1/4" NPT female |
A | |
|
2D drawings
3D models
Tender text
CALEFFI, 116170A, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
Complete with:
Low lead/ lead free brass balancing valve
Cavity for bypass cartridge
Model Options:
A: Valve only
B: + Isolation valves only
C: + Outlet check valve only
D: + Isolation valves & check valve
E: + Temperature gauge only
F: + Gauge & Isolation valves
G: + Gauge & check valve
H: + Gauge, Isolation valves & check valve
Connection Options:
Sizes: 1”, 1 ¼”
Connection Type: NPT Female
Accessories (sold separately):
Insulation jacket
Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Material: DZR low lead brass.
SCIP code
CODE UNDER ANALYSIS
|
|||
| 116160A 001 | 1" NPT female |
B | |
|
3D models
Tender text
CALEFFI, 116160A 001, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
For use in domestic hot water recirculation circuits
Complete with:
Cavity for bypass cartridge
Optional:
Outlet check valve
Isolation valves
Temperature gauge
connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
|
|||
| 116170A 001 | 1 1/4" NPT female |
B | |
|
3D models
Tender text
CALEFFI, 116170A 001, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
For use in domestic hot water recirculation circuits
Complete with:
Cavity for bypass cartridge
Optional:
Outlet check valve
Isolation valves
Temperature gauge
connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
|
|||
| 116160AC | 1" NPT female |
C | |
|
3D models
Tender text
CALEFFI, 116160AC, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
Complete with:
Low lead/ lead free brass balancing valve
Cavity for bypass cartridge
Model Options:
A: Valve only
B: + Isolation valves only
C: + Outlet check valve only
D: + Isolation valves & check valve
E: + Temperature gauge only
F: + Gauge & Isolation valves
G: + Gauge & check valve
H: + Gauge, Isolation valves & check valve
Connection Options:
Sizes: 1”, 1 ¼”
Connection Type: NPT Female
Accessories (sold separately):
Insulation jacket
Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: C. Material: DZR low lead brass.
|
|||
| 116170AC | 1 1/4" NPT female |
C | |
|
3D models
Tender text
CALEFFI, 116170AC, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
Complete with:
Low lead/ lead free brass balancing valve
Cavity for bypass cartridge
Model Options:
A: Valve only
B: + Isolation valves only
C: + Outlet check valve only
D: + Isolation valves & check valve
E: + Temperature gauge only
F: + Gauge & Isolation valves
G: + Gauge & check valve
H: + Gauge, Isolation valves & check valve
Connection Options:
Sizes: 1”, 1 ¼”
Connection Type: NPT Female
Accessories (sold separately):
Insulation jacket
Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: C. Material: DZR low lead brass.
|
|||
| 116160AC 001 | 1" NPT female |
D | |
|
3D models
Tender text
CALEFFI, 116160AC 001, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
For use in domestic hot water recirculation circuits
Complete with:
Cavity for bypass cartridge
Optional:
Outlet check valve
Isolation valves
Temperature gauge
connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
|
|||
| 116170AC 001 | 1 1/4" NPT female |
D | |
|
3D models
Tender text
CALEFFI, 116170AC 001, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
For use in domestic hot water recirculation circuits
Complete with:
Cavity for bypass cartridge
Optional:
Outlet check valve
Isolation valves
Temperature gauge
connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
|
|||
| 116161A | 1" NPT female |
E | |
|
3D models
Tender text
CALEFFI, 116161A, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
Complete with:
Low lead/ lead free brass balancing valve
Cavity for bypass cartridge
Model Options:
A: Valve only
B: + Isolation valves only
C: + Outlet check valve only
D: + Isolation valves & check valve
E: + Temperature gauge only
F: + Gauge & Isolation valves
G: + Gauge & check valve
H: + Gauge, Isolation valves & check valve
Connection Options:
Sizes: 1”, 1 ¼”
Connection Type: NPT Female
Accessories (sold separately):
Insulation jacket
Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: E. Material: DZR low lead brass.
|
|||
| 116171A | 1 1/4" NPT female |
E | |
|
3D models
Tender text
CALEFFI, 116171A, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
Complete with:
Low lead/ lead free brass balancing valve
Cavity for bypass cartridge
Model Options:
A: Valve only
B: + Isolation valves only
C: + Outlet check valve only
D: + Isolation valves & check valve
E: + Temperature gauge only
F: + Gauge & Isolation valves
G: + Gauge & check valve
H: + Gauge, Isolation valves & check valve
Connection Options:
Sizes: 1”, 1 ¼”
Connection Type: NPT Female
Accessories (sold separately):
Insulation jacket
Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: E. Material: DZR low lead brass.
|
|||
| 116161A 001 | 1" NPT female |
F | |
|
3D models
Tender text
CALEFFI, 116161A 001, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
For use in domestic hot water recirculation circuits
Complete with:
Cavity for bypass cartridge
Optional:
Outlet check valve
Isolation valves
Temperature gauge
connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
|
|||
| 116171A 001 | 1 1/4" NPT female |
F | |
|
3D models
Tender text
CALEFFI, 116171A 001, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
For use in domestic hot water recirculation circuits
Complete with:
Cavity for bypass cartridge
Optional:
Outlet check valve
Isolation valves
Temperature gauge
connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
|
|||
| 116161AC | 1" NPT female |
G | |
|
3D models
Tender text
CALEFFI, 116161AC, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
Complete with:
Low lead/ lead free brass balancing valve
Cavity for bypass cartridge
Model Options:
A: Valve only
B: + Isolation valves only
C: + Outlet check valve only
D: + Isolation valves & check valve
E: + Temperature gauge only
F: + Gauge & Isolation valves
G: + Gauge & check valve
H: + Gauge, Isolation valves & check valve
Connection Options:
Sizes: 1”, 1 ¼”
Connection Type: NPT Female
Accessories (sold separately):
Insulation jacket
Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: G. Material: DZR low lead brass.
|
|||
| 116171AC | 1 1/4" NPT female |
G | |
|
3D models
Tender text
CALEFFI, 116171AC, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
Complete with:
Low lead/ lead free brass balancing valve
Cavity for bypass cartridge
Model Options:
A: Valve only
B: + Isolation valves only
C: + Outlet check valve only
D: + Isolation valves & check valve
E: + Temperature gauge only
F: + Gauge & Isolation valves
G: + Gauge & check valve
H: + Gauge, Isolation valves & check valve
Connection Options:
Sizes: 1”, 1 ¼”
Connection Type: NPT Female
Accessories (sold separately):
Insulation jacket
Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: G. Material: DZR low lead brass.
|
|||
| 116161AC 001 | 1" NPT female |
H | |
|
3D models
Tender text
CALEFFI, 116161AC 001, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
For use in domestic hot water recirculation circuits
Complete with:
Cavity for bypass cartridge
Optional:
Outlet check valve
Isolation valves
Temperature gauge
connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
|
|||
| 116171AC 001 | 1 1/4" NPT female |
H | |
|
3D models
Tender text
CALEFFI, 116171AC 001, ThermoSetter™.
Adjustable thermal balancing valve with thermal disinfection capability
For use in domestic hot water recirculation circuits
Complete with:
Cavity for bypass cartridge
Optional:
Outlet check valve
Isolation valves
Temperature gauge
connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Material: DZR low lead brass.
|
|||