Series 6003

LEGIOMIX®evo flange, Digital mixing valve

600360A.png
Download high resolution

Product Description

Digital mixing valve
Point-of-distribution applications - ASSE 1017

Complete with:

  • Mixing valve and actuator
  • Digital controller
  • 3 temperature sensors
  • 50 VA Transformer
     

Model Options:
A: Fail-safe actuator, 0- 10 V Control
B: Fail-in-place actuator, 0 - 10 V Control
 
Connection Options:

  • Sizes: 2-½” and 3”
  • Connection Type: ANSI 150 Flange
     

Accessories (sold separately):

  • Emergency shutoff valve
  • Alarm indication station
     

Technical data

Material: DZR low lead brass
Electric supply: 24 V AC
Maximum working pressure: 150 psi
Maximum inlet temperature: 212 °F
Temperature adjustment range: 70 – 185 °F
Low Lead

Note

For commercial domestic hot water systems requiring precision temperature control and reliable Legionella prevention. The LEGIOMIXevo combines advanced digital technology with our proven hydronic expertise to deliver consistent water temperatures, operational safety, and energy efficiency in demanding environments such as hospitals, schools, hotels, and more.

 

  • Enhanced Safety and Reliability: The fail-safe actuator shuts off the hot water supply during power failures, ensuring safety and reducing liability risks.
  • Precision Tempered Water Management: Advanced intelligence, programmed scheduling, built-in data logging, and Legionella management ensure accurate performance and compliance. Allowing you to execute your water management plan with confidence.
  • Fast Hassle-Free Setup: A user-friendly touchscreen eliminates manual calibration and complex configuration. No laptop is needed to ensure quick and easy installation and commissioning.
  • Minimize Maintenance with Automatic Descaling: Reduces total cost of ownership with automated descaling of the ball control element preventing scale buildup and ensuring consistent temperature stability for dependable long-term operation.
  • Remote Diagnostics and System Optimization: Cloud and BMS connectivity enable real-time monitoring, remote diagnostics, and setpoint adjustments. Control the system performance and troubleshoot issues to reduce maintenance downtime and improve efficiency.
  • Minimal Downtime: Designed for quick retrofits, the feature-rich controller functions as a standalone mixing system and the Posi-Stop unions or ANSI 150 flanges simplify piping connections.

Services and Connectivity

Certifications

ASSE 1017 Listed
cUPC
NSF/ANSI/CAN 61
NSF/ANSI/CAN 372
ES LOW LEAD
CE
BACnet Listed

Drawings and specifications

Part number Connection Cv Model Actions
600360AF 2 1/2" ANSI 150 flange
105 A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 600360AF, LEGIOMIX®evo flange. Digital mixing valve Point-of-distribution applications - ASSE 1017 Complete with: Mixing valve and actuator Digital controller 3 temperature sensors 50 VA Transformer   Model Options: A: Fail-safe actuator, 0- 10 V Control B: Fail-in-place actuator, 0 - 10 V Control   Connection Options: Sizes: 2-½” and 3” Connection Type: ANSI 150 Flange   Accessories (sold separately): Emergency shutoff valve Alarm indication station   Connection: 2 1/2" ANSI 150 flange. Maximum working pressure: 150 psi. Temperature adjustment range: 70 – 185 °F. Maximum inlet temperature: 212 °F. Electric supply: 24 V AC. Model: A. Cv: 105. Material: DZR low lead brass.
600380AF 3" ANSI 150 flange
120 A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 600380AF, LEGIOMIX®evo flange. Digital mixing valve Point-of-distribution applications - ASSE 1017 Complete with: Mixing valve and actuator Digital controller 3 temperature sensors 50 VA Transformer   Model Options: A: Fail-safe actuator, 0- 10 V Control B: Fail-in-place actuator, 0 - 10 V Control   Connection Options: Sizes: 2-½” and 3” Connection Type: ANSI 150 Flange   Accessories (sold separately): Emergency shutoff valve Alarm indication station   Connection: 3" ANSI 150 flange. Maximum working pressure: 150 psi. Temperature adjustment range: 70 – 185 °F. Maximum inlet temperature: 212 °F. Electric supply: 24 V AC. Model: A. Cv: 120. Material: DZR low lead brass.
600360A 2 1/2" ANSI 150 flange
105 B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 600360A, LEGIOMIX®evo flange. Digital mixing valve Point-of-distribution applications - ASSE 1017 Complete with: Mixing valve and actuator Digital controller 3 temperature sensors 50 VA Transformer   Model Options: A: Fail-safe actuator, 0- 10 V Control B: Fail-in-place actuator, 0 - 10 V Control   Connection Options: Sizes: 2-½” and 3” Connection Type: ANSI 150 Flange   Accessories (sold separately): Emergency shutoff valve Alarm indication station   Connection: 2 1/2" ANSI 150 flange. Maximum working pressure: 150 psi. Temperature adjustment range: 70 – 185 °F. Maximum inlet temperature: 212 °F. Electric supply: 24 V AC. Model: B. Cv: 105. Material: DZR low lead brass.
600380A 3" ANSI 150 flange
120 B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 600380A, LEGIOMIX®evo flange. Digital mixing valve Point-of-distribution applications - ASSE 1017 Complete with: Mixing valve and actuator Digital controller 3 temperature sensors 50 VA Transformer   Model Options: A: Fail-safe actuator, 0- 10 V Control B: Fail-in-place actuator, 0 - 10 V Control   Connection Options: Sizes: 2-½” and 3” Connection Type: ANSI 150 Flange   Accessories (sold separately): Emergency shutoff valve Alarm indication station   Connection: 3" ANSI 150 flange. Maximum working pressure: 150 psi. Temperature adjustment range: 70 – 185 °F. Maximum inlet temperature: 212 °F. Electric supply: 24 V AC. Model: B. Cv: 120. Material: DZR low lead brass.

Applications

Caleffi Rep Locator
Caleffi Rep Locator

Find your nearest Caleffi Representative