Product Description

Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:

  • Low lead/ lead free brass balancing valve
  • Thermal disinfection bypass cartridge
  • Outlet temperature gauge

Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:

  • Sizes: 1”, 1 ¼”
  • Connection Types: NPT Female

Accessories (sold seperately):

  • Insulation jacket

Technical data

Material: DZR low lead brass
Maximum working pressure: 230 psi
Maximum inlet temperature: 195 °F
Temperature adjustment range: 95 – 150 °F
Low Lead

Drawings and specifications

Part number Connection Model Actions
116260A 1" NPT female
A
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 116260A, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Material: DZR low lead brass.
SCIP code
CODE UNDER ANALYSIS
116270A 1 1/4" NPT female
A
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 116270A, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Material: DZR low lead brass.
SCIP code
CODE UNDER ANALYSIS
116260A 001 1" NPT female
B
3D models
Tender text
CALEFFI, 116260A 001, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge For use in domestic hot water recirculation circuits Complete with: Thermal disinfection bypass cartridge Temperature gauge Optional: Outlet check valve Isolation valves connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3. Material: DZR low lead brass.
116270A 001 1 1/4" NPT female
B
3D models
Tender text
CALEFFI, 116270A 001, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge For use in domestic hot water recirculation circuits Complete with: Thermal disinfection bypass cartridge Temperature gauge Optional: Outlet check valve Isolation valves connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3. Material: DZR low lead brass.
116260AC 1" NPT female
C
3D models
Tender text
CALEFFI, 116260AC, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: C. Material: DZR low lead brass.
116270AC 1 1/4" NPT female
C
3D models
Tender text
CALEFFI, 116270AC, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: C. Material: DZR low lead brass.
116260AC 001 1" NPT female
D
3D models
Tender text
CALEFFI, 116260AC 001, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge For use in domestic hot water recirculation circuits Complete with: Thermal disinfection bypass cartridge Temperature gauge Optional: Outlet check valve Isolation valves connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3. Material: DZR low lead brass.
116270AC 001 1 1/4" NPT female
D
3D models
Tender text
CALEFFI, 116270AC 001, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge For use in domestic hot water recirculation circuits Complete with: Thermal disinfection bypass cartridge Temperature gauge Optional: Outlet check valve Isolation valves connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3. Material: DZR low lead brass.
116660A 1" NPT female
E
3D models
Tender text
CALEFFI, 116660A, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: E. Material: DZR low lead brass.
116670A 1 1/4" NPT female
E
3D models
Tender text
CALEFFI, 116670A, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: E. Material: DZR low lead brass.
116660A 001 1" NPT female
F
3D models
Tender text
CALEFFI, 116660A 001, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: F. Material: DZR low lead brass.
116670A 001 1 1/4" NPT female
F
3D models
Tender text
CALEFFI, 116670A 001, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: F. Material: DZR low lead brass.
116660AC 1" NPT female
G
3D models
Tender text
CALEFFI, 116660AC, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: G. Material: DZR low lead brass.
116670AC 1 1/4" NPT female
G
3D models
Tender text
CALEFFI, 116670AC, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: G. Material: DZR low lead brass.
116660AC 001 1" NPT female
H
3D models
Tender text
CALEFFI, 116660AC 001, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: H. Material: DZR low lead brass.
116670AC 001 1 1/4" NPT female
H
3D models
Tender text
CALEFFI, 116670AC 001, ThermoSetter™. Adjustable thermal balancing valve with disinfection bypass cartridge Complete with: Low lead/ lead free brass balancing valve Thermal disinfection bypass cartridge Outlet temperature gauge Model Options: A: 160°F Bypass B: 160°F Bypass, Isolation valves C: 160°F Bypass, outlet check valve D: 160°F Bypass, check valve, isolation valves E: 140°F Bypass F: 140°F Bypass, isolation valves G: 140°F Bypass, outlet check valve H: 140°F Bypass, check valve, isolation valves Connection Options: Sizes: 1”, 1 ¼” Connection Types: NPT Female Accessories (sold seperately): Insulation jacket Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: H. Material: DZR low lead brass.

Applications

Caleffi Rep Locator
Caleffi Rep Locator

Find your nearest Caleffi Representative