ThermoSetter™, Adjustable thermal balancing valve with disinfection bypass cartridge
Product Description
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
- Low lead/ lead free brass balancing valve
- Thermal disinfection bypass cartridge
- Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
- Sizes: 1”, 1 ¼”
- Connection Types: NPT Female
Accessories (sold seperately):
- Insulation jacket
Technical data
Material:
DZR low lead brass
Maximum working pressure:
230 psi
Maximum inlet temperature:
195 °F
Temperature adjustment range:
95 – 150 °F
Download
Drawings and specifications
| Part number | Connection | Model | Actions |
|---|---|---|---|
| 116260A | 1" NPT female |
A | |
|
2D drawings
3D models
Tender text
CALEFFI, 116260A, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Material: DZR low lead brass.
SCIP code
CODE UNDER ANALYSIS
|
|||
| 116270A | 1 1/4" NPT female |
A | |
|
2D drawings
3D models
Tender text
CALEFFI, 116270A, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Material: DZR low lead brass.
SCIP code
CODE UNDER ANALYSIS
|
|||
| 116260A 001 | 1" NPT female |
B | |
|
3D models
Tender text
CALEFFI, 116260A 001, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
For use in domestic hot water recirculation circuits
Complete with:
Thermal disinfection bypass cartridge
Temperature gauge
Optional:
Outlet check valve
Isolation valves
connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3. Material: DZR low lead brass.
|
|||
| 116270A 001 | 1 1/4" NPT female |
B | |
|
3D models
Tender text
CALEFFI, 116270A 001, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
For use in domestic hot water recirculation circuits
Complete with:
Thermal disinfection bypass cartridge
Temperature gauge
Optional:
Outlet check valve
Isolation valves
connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3. Material: DZR low lead brass.
|
|||
| 116260AC | 1" NPT female |
C | |
|
3D models
Tender text
CALEFFI, 116260AC, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: C. Material: DZR low lead brass.
|
|||
| 116270AC | 1 1/4" NPT female |
C | |
|
3D models
Tender text
CALEFFI, 116270AC, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: C. Material: DZR low lead brass.
|
|||
| 116260AC 001 | 1" NPT female |
D | |
|
3D models
Tender text
CALEFFI, 116260AC 001, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
For use in domestic hot water recirculation circuits
Complete with:
Thermal disinfection bypass cartridge
Temperature gauge
Optional:
Outlet check valve
Isolation valves
connection: 1" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3. Material: DZR low lead brass.
|
|||
| 116270AC 001 | 1 1/4" NPT female |
D | |
|
3D models
Tender text
CALEFFI, 116270AC 001, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
For use in domestic hot water recirculation circuits
Complete with:
Thermal disinfection bypass cartridge
Temperature gauge
Optional:
Outlet check valve
Isolation valves
connection: 1 1/4" NPT female. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3. Material: DZR low lead brass.
|
|||
| 116660A | 1" NPT female |
E | |
|
3D models
Tender text
CALEFFI, 116660A, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: E. Material: DZR low lead brass.
|
|||
| 116670A | 1 1/4" NPT female |
E | |
|
3D models
Tender text
CALEFFI, 116670A, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: E. Material: DZR low lead brass.
|
|||
| 116660A 001 | 1" NPT female |
F | |
|
3D models
Tender text
CALEFFI, 116660A 001, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: F. Material: DZR low lead brass.
|
|||
| 116670A 001 | 1 1/4" NPT female |
F | |
|
3D models
Tender text
CALEFFI, 116670A 001, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: F. Material: DZR low lead brass.
|
|||
| 116660AC | 1" NPT female |
G | |
|
3D models
Tender text
CALEFFI, 116660AC, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: G. Material: DZR low lead brass.
|
|||
| 116670AC | 1 1/4" NPT female |
G | |
|
3D models
Tender text
CALEFFI, 116670AC, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: G. Material: DZR low lead brass.
|
|||
| 116660AC 001 | 1" NPT female |
H | |
|
3D models
Tender text
CALEFFI, 116660AC 001, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: H. Material: DZR low lead brass.
|
|||
| 116670AC 001 | 1 1/4" NPT female |
H | |
|
3D models
Tender text
CALEFFI, 116670AC 001, ThermoSetter™.
Adjustable thermal balancing valve with disinfection bypass cartridge
Complete with:
Low lead/ lead free brass balancing valve
Thermal disinfection bypass cartridge
Outlet temperature gauge
Model Options:
A: 160°F Bypass
B: 160°F Bypass, Isolation valves
C: 160°F Bypass, outlet check valve
D: 160°F Bypass, check valve, isolation valves
E: 140°F Bypass
F: 140°F Bypass, isolation valves
G: 140°F Bypass, outlet check valve
H: 140°F Bypass, check valve, isolation valves
Connection Options:
Sizes: 1”, 1 ¼”
Connection Types: NPT Female
Accessories (sold seperately):
Insulation jacket
Connection: 1 1/4" NPT female. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: H. Material: DZR low lead brass.
|
|||