ThermoSetter™, Adjustable thermal balancing valve with actuator enabled disinfection cartridge
Product Description
Adjustable thermal balancing valve with actuator enabled disinfection cartridge
Complete with:
- Low lead / lead free brass balancing valve
- Integral outlet check valve
- Outlet temperature gauge
- Actuator driven bypass cartridge
Model Options:
A: Valve and actuator cartridge
B: + Isolation Valves
C: + Isolation valves & Y-strainer
Connection Options:
- Sizes: ½", ¾"
- Connection Types: Press, Sweat, NPT Female, PEX Crimp, PEX Expansion
Accessories (sold separately):
- Insulation jacket
- 656 Series Thermo-electric actuator
Technical data
Material:
DZR low lead brass
Disinfection Cv:
1.2
Min Cv:
0.23
Max Cv:
2.1
Temperature adjustment range:
95 – 140 °F
Maximum working pressure:
230 psi
Certifications
Download
Drawings and specifications
| Part number | Connection | Note | Actions |
|---|---|---|---|
| 116340AC 002 | 1/2" NPT female union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116340AC 002, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (NPT)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 1/2" NPT female, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116340AC 006 | 1/2" Press union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116340AC 006, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (press)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 1/2" Press, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116340AC 007 | 1/2" PEX crimp union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116340AC 007, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (PEX)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 1/2" PEX crimp, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116340AC 008 | 1/2" PEX expansion union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116340AC 008, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (PEX)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 1/2" PEX expansion, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116340AC 009 | 1/2" Sweat union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116340AC 009, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (sweat)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 1/2" Sweat, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116350AC 002 | 3/4" NPT female union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116350AC 002, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (NPT)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 3/4" NPT female, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116350AC 006 | 3/4" Press union |
- | |
|
3D models
Tender text
CALEFFI, 116350AC 006, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (press)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 3/4" Press, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116350AC 007 | 3/4" PEX crimp union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116350AC 007, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (PEX)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 3/4" PEX crimp, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116350AC 008 | 3/4" PEX expansion union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116350AC 008, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (PEX)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 3/4" PEX expansion, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116350AC 009 | 3/4" Sweat union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116350AC 009, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (sweat)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 3/4" Sweat, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116340AC 102 | 1/2" NPT female union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116340AC 102, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (NPT)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 1/2" NPT female, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116340AC 106 | 1/2" Press union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116340AC 106, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (press)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 1/2" Press, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116340AC 107 | 1/2" PEX crimp union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116340AC 107, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (PEX)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 1/2" PEX crimp, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116340AC 108 | 1/2" PEX expansion union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116340AC 108, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (PEX)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 1/2" PEX expansion, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116340AC 109 | 1/2" Sweat union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116340AC 109, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (sweat)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 1/2" Sweat, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116350AC 102 | 3/4" NPT female union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116350AC 102, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (NPT)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 3/4" NPT female, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116350AC 106 | 3/4" Press union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116350AC 106, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (press)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 3/4" Press, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116350AC 107 | 3/4" PEX crimp union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116350AC 107, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (PEX)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 3/4" PEX crimp, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116350AC 108 | 3/4" PEX expansion union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116350AC 108, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (PEX)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 3/4" PEX expansion, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116350AC 109 | 3/4" Sweat union |
$$ data missing $$ | |
|
3D models
Tender text
CALEFFI, 116350AC 109, ThermoSetter™.
Adjustable thermal balancing valve for thermal disinfection using electronic actuator (sweat)
For use in domestic hot water recirculation circuits
Dual union connections
Complete with:
Thermo-electric bypass valve
Outlet check valves
Temperature gauge
Optional:
Union isolation valves
656 series actuator for bypass valve sold separately
Connection: 3/4" Sweat, union. Maximum working pressure: 230 psi. Temperature adjustment range: 95 – 140 °F. Max Cv: 2.1. Min Cv: 0.23. Disinfection Cv: 1.2. Material: DZR low lead brass.
|
|||
| 116340AC 112 | 1/2" NPT female union |
$$ data missing $$ | |
|
3D models
|
|||
| 116340AC 116 | 1/2" Press union |
$$ data missing $$ | |
|
3D models
|
|||
| 116340AC 117 | 1/2" PEX crimp union |
$$ data missing $$ | |
|
3D models
|
|||
| 116340AC 118 | 1/2" PEX expansion union |
$$ data missing $$ | |
|
3D models
|
|||
| 116340AC 119 | 1/2" Sweat union |
$$ data missing $$ | |
|
3D models
|
|||
| 116350AC 112 | 3/4" NPT female union |
$$ data missing $$ | |
|
3D models
|
|||
| 116350AC 116 | 3/4" Press union |
$$ data missing $$ | |
|
3D models
|
|||
| 116350AC 117 | 3/4" PEX crimp union |
$$ data missing $$ | |
|
3D models
|
|||
| 116350AC 118 | 3/4" PEX expansion union |
$$ data missing $$ | |
|
3D models
|
|||
| 116350AC 119 | 3/4" Sweat union |
$$ data missing $$ | |
|
3D models
|
|||