Series 520

AngleMix™, Angled thermostatic mixing valve

520410A.png
520410A.png
Download high resolution

Product Description

Angled thermostatic mixing valve
Point-of-distribution applications – ASSE 1017
 
Model Options:
A: Valve and Outlet Temp. Gauge
B: + Inlet Check Valves
 
Connection Options:

  • Sizes: ½", ¾", 1"
  • Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion

Technical data

Material: DZR low lead brass
Cv: 2.0
Maximum working pressure: 150 psi
Maximum inlet temperature: 195 °F
Temperature adjustment range: 95 – 150 °F
Low Lead

Note

*Meets the "lead free" requirement of Section 1417 of the Safe Drinking Water Act (SDWA). This product has a weighted average lead content of less than 0.25% for its wetted surfaces contacted with consumable water.

Certifications

ASSE1017
CSA 125.3 Compliant
NSF/ANSI/CAN 372
ES LOW LEAD

Drawings and specifications

Part number Connection Model Actions
520410A 1/2" NPT male
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520410A, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1/2" NPT male, union. Maximum working pressure: 150 psi. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520414A 1/2" PEX crimp
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520414A, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1/2" PEX crimp, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520415A 1/2" PEX expansion
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520415A, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1/2" PEX expansion, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520416A 1/2" Press
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520416A, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1/2" Press, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520419A 1/2" Sweat
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520419A, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1/2" Sweat, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520510A 3/4" NPT male
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520510A, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 3/4" NPT male, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520514A 3/4" PEX crimp
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520514A, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 3/4" PEX crimp, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520515A 3/4" PEX expansion
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520515A, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 3/4" PEX expansion, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520516A 3/4" Press
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520516A, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 3/4" Press, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520519A 3/4" Sweat
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520519A, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 3/4" Sweat, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520610A 001 1" NPT male
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520610A 001, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1" NPT male, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520614A 001 1" PEX crimp
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520614A 001, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1" PEX crimp, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520615A 001 1" PEX expansion
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520615A 001, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1" PEX expansion, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520616A 001 1" Press
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520616A 001, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1" Press, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520619A 001 1" Sweat
union
A
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520619A 001, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1" Sweat, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: A. Cv: 2.0. Material: DZR low lead brass.
520410AC 1/2" NPT male
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520410AC, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1/2" NPT male, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520414AC 1/2" PEX crimp
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520414AC, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1/2" PEX crimp, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520415AC 1/2" PEX expansion
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520415AC, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1/2" PEX expansion, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520416AC 1/2" Press
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520416AC, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1/2" Press, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520419AC 1/2" Sweat
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520419AC, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1/2" Sweat, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520510AC 3/4" NPT male
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520510AC, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 3/4" NPT male, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520514AC 3/4" PEX crimp
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520514AC, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 3/4" PEX crimp, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520515AC 3/4" PEX expansion
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520515AC, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 3/4" PEX expansion, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520516AC 3/4" Press
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520516AC, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 3/4" Press, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520519AC 3/4" Sweat
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520519AC, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 3/4" Sweat, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520610AC 001 1" NPT male
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520610AC 001, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1" NPT male, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520614AC 001 1" PEX crimp
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520614AC 001, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1" PEX crimp, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520615AC 001 1" PEX expansion
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520615AC 001, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1" PEX expansion, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520616AC 001 1" Press
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520616AC 001, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1" Press, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520619AC 001 1" Sweat
union
B
2D drawings
Download
3D models
Download
Download
Tender text
CALEFFI, 520619AC 001, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1" Sweat, union. Temperature adjustment range: 95 – 150 °F. Maximum inlet temperature: 195 °F. Model: B. Cv: 2.0. Material: DZR low lead brass.
520051A 1" G (ISO 228-1A) M
Body only
3D models
Tender text
CALEFFI, 520051A, AngleMix™. Angled thermostatic mixing valve Point-of-distribution applications – ASSE 1017   Model Options: A: Valve and Outlet Temp. Gauge B: + Inlet Check Valves   Connection Options: Sizes: ½", ¾", 1" Connection Types: Press, Sweat, NPT Male, PEX Crimp, PEX Expansion Connection: 1" G (ISO 228-1A) M. Model: Body only. Cv: 2.0.

Applications

Caleffi Rep Locator
Caleffi Rep Locator

Find your nearest Caleffi Representative