Pump station for solar thermal systems, return connection.
Product Description
Pump station for solar thermal systems, return connection.
Complete with:
- Solar circulation pump;
- 253 series safety relief valve for solar thermal systems;
- filler/drain cock;
- instrument holder fitting with pressure gauge;
- flow meter;
- return temperature gauge;
- shut-off and check valve;
- 2 hose connections.
(For other settings refer to 253 series using adapter code F21224).
With PWM control.
With insulation.
Technical data
Maximum working pressure:
10 bar
Medium temperature range:
-10–110 °C
Setting:
6 bar
Electric supply:
230 V (AC)
Maximum percentage of glycol:
50 %
Medium:
water, glycol solutions
Certifications
Download
Drawings and specifications
Part number | Connection | Note | Flow meter scale |
---|---|---|---|
278050HE | G 3/4" (ISO 228-1) F |
With PWM control | 1–13 l/min |
Type of pump
UPM3 15-75
|
|||
3D models
Tender text
Pump station for solar thermal systems, return connection. With insulation.
Complete with:
- Solar circulation pump;
- 253 series safety relief valve for solar thermal systems;
- filler/drain cock;
- instrument holder fitting with pressure gauge;
- flow meter;
- return temperature gauge;
- shut-off and check valve;
- 2 hose connections.
(For other settings refer to 253 series using adapter code F21224).
With PWM control. Connection: G 3/4" (ISO 228-1) F. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Setting: 6 bar. Electric supply: 230 V (AC). Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Flow meter scale: 1–13 l/min. Type of pump: UPM3 15-75.
SCIP code
db9a8f7e-6e83-42c0-8b99-d33261e2423f
|
|||
278052HE | G 3/4" (ISO 228-1) F |
- | 8–30 l/min |
Type of pump
UPM3 15-75
|
|||
3D models
Tender text
Pump station for solar thermal systems, return connection. With insulation.
Complete with:
- Solar circulation pump;
- 253 series safety relief valve for solar thermal systems;
- filler/drain cock;
- instrument holder fitting with pressure gauge;
- flow meter;
- return temperature gauge;
- shut-off and check valve;
- 2 hose connections.
(For other settings refer to 253 series using adapter code F21224).
With PWM control. Connection: G 3/4" (ISO 228-1) F. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Setting: 6 bar. Electric supply: 230 V (AC). Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Flow meter scale: 8–30 l/min. Type of pump: UPM3 15-75.
SCIP code
9856e556-3fac-4b38-8649-610801f872c7
|