Technical data

Maximum upstream pressure: 2500 kPa
Medium temperature range: 2–80 °C
Adjustment pressure range: 600–1000 kPa
Material: dezincification resistant brass DR

Certifications

AUS AS1357.2 WM-40299
WRAS

Drawings and specifications

Part number Connection
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pressure reducing valve for first stage control, with replaceable cartridge. Piston operation. With pressure gauge: 0–2500 kPa. Connection: R 1/2" (EN 10226-1) M, union. Maximum upstream pressure: 2500 kPa. Medium temperature range: 2–80 °C. Adjustment pressure range: 600–1000 kPa. Material: dezincification resistant brass DR.
SCIP code
1ea6b9c8-5313-46bd-aeb2-9863870ab259
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pressure reducing valve for first stage control, with replaceable cartridge. Piston operation. With pressure gauge: 0–2500 kPa. Connection: R 3/4" (EN 10226-1) M, union. Maximum upstream pressure: 2500 kPa. Medium temperature range: 2–80 °C. Adjustment pressure range: 600–1000 kPa. Material: dezincification resistant brass DR.
SCIP code
7d696fa5-b405-4e21-9faf-eebeb09cc609
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pressure reducing valve for first stage control, with replaceable cartridge. Piston operation. With pressure gauge: 0–2500 kPa. Connection: R 1" (EN 10226-1) M, union. Maximum upstream pressure: 2500 kPa. Medium temperature range: 2–80 °C. Adjustment pressure range: 600–1000 kPa. Material: dezincification resistant brass DR.
SCIP code
67db59dd-7035-4794-ad78-c4c7ff892527
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pressure reducing valve for first stage control, with replaceable cartridge. Piston operation. With pressure gauge: 0–2500 kPa. Connection: R 1 1/4" (EN 10226-1) M, union. Maximum upstream pressure: 2500 kPa. Medium temperature range: 2–80 °C. Adjustment pressure range: 600–1000 kPa. Material: dezincification resistant brass DR.
SCIP code
ece2ae5c-3db3-4048-9cd8-8afdb5c11ee8
2D drawings
Download
Download
3D models
Download
Download
Tender text
Pressure reducing valve for first stage control, with replaceable cartridge. Piston operation. With pressure gauge: 0–2500 kPa. Connection: R 1 1/2" (EN 10226-1) M, union. Maximum upstream pressure: 2500 kPa. Medium temperature range: 2–80 °C. Adjustment pressure range: 600–1000 kPa. Material: dezincification resistant brass DR.