Series Z-one

Z-one™, 2-way motorized zone valve (with screw terminal connection)

Go to
Z50.png
Z50.png
Download high resolution

Product Description

2-way motorized zone valve (with screw terminal connection)
UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251.
Normally closed actuator: Z151000.
Spring return.
Auxiliary micro-switch.
With auxiliary microswitch.

Technical data

Maximum working pressure: 300 psi
Medium temperature range: 32–240 °F
Electric supply: 24 V (AC)
Power consumption: 7 VA
Auxiliary microswitch contact rating (24 V): 0.4 A
Maximum percentage of glycol: 50 %
Medium: water, glycol solutions, vapor (max. 15 psi)

Drawings and specifications

Part number Connection Note △p max.
3D models
Tender text
2-way motorized zone valve (with screw terminal connection) With auxiliary microswitch. UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator: Z151000. Spring return. Auxiliary micro-switch. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 30 psi. Cv: 3.5 gpm.
Cv
3.5 gpm
3D models
Tender text
2-way motorized zone valve (with screw terminal connection) With auxiliary microswitch. UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator: Z151000. Spring return. Auxiliary micro-switch. Connection: 3/4". Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 30 psi. Cv: 3.5 gpm.
3D models
Tender text
2-way motorized zone valve (with screw terminal connection) With auxiliary microswitch. UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator: Z151000. Spring return. Auxiliary micro-switch. Connection: 1/2", sweat. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 50 psi. Cv: 2.5 gpm.
3D models
Tender text
2-way motorized zone valve (with screw terminal connection) With auxiliary microswitch. UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator: Z151000. Spring return. Auxiliary micro-switch. Connection: 3/4", sweat. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 20 psi. Cv: 7.5 gpm.
3D models
Tender text
2-way motorized zone valve (with screw terminal connection) With auxiliary microswitch. UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator: Z151000. Spring return. Auxiliary micro-switch. Connection: 1", sweat. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 20 psi. Cv: 7.5 gpm.
3D models
Tender text
2-way motorized zone valve (with screw terminal connection) With auxiliary microswitch. UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator: Z151000. Spring return. Auxiliary micro-switch. Connection: 1 1/4", sweat. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 20 psi. Cv: 7.5 gpm.

Applications

DWS

Caleffi Domestic Water Sizer allows fast and correct sizing of the main components of domestic water systems.

Caleffi Rep Locator
Caleffi Rep Locator

Find your nearest Caleffi Representative