Series 676

TwisTop™, 2-way thermo-electric zone valve

Go to
676256A.png
676256A.png
Download high resolution

Product Description

2-way thermo-electric zone valve
Two-way thermo-electric zone valve. Complete with TwisTop™ (code 656354) actuator.
Brass trim.
Spring return. Normally closed.
Power consumption: holding: 3 W.
Power consumption: inrush: 6 VA.

Technical data

Maximum working pressure: 150 psi
Medium temperature range: 32–200 °F
Electric supply: 24 V (AC) / (DC)
Starting current: ≤ 250 mA
Auxiliary microswitch contact rating (24 V): 5 A
△p max.: 20 psi
Material: brass

Drawings and specifications

Part number Connection Note Cv
3D models
Tender text
2-way thermo-electric zone valve Two-way thermo-electric zone valve. Complete with TwisTop™ (code 656354) actuator. Brass trim. Spring return. Normally closed. Power consumption: holding: 3 W. Power consumption: inrush: 6 VA. Connection: 3/4", press union. Maximum working pressure: 150 psi. Medium temperature range: 32–200 °F. Electric supply: 24 V (AC) / (DC). Starting current: ≤ 250 mA. Auxiliary microswitch contact rating (24 V): 5 A. △p max.: 20 psi. Cv: 4.0 gpm.
3D models
Tender text
2-way thermo-electric zone valve Two-way thermo-electric zone valve. Complete with TwisTop™ (code 656354) actuator. Brass trim. Spring return. Normally closed. Power consumption: holding: 3 W. Power consumption: inrush: 6 VA. Connection: 3/4", sweat union. Maximum working pressure: 150 psi. Medium temperature range: 32–200 °F. Electric supply: 24 V (AC) / (DC). Starting current: ≤ 250 mA. Auxiliary microswitch contact rating (24 V): 5 A. △p max.: 20 psi. Cv: 4.0 gpm.
3D models
Tender text
2-way thermo-electric zone valve Two-way thermo-electric zone valve. Complete with TwisTop™ (code 656354) actuator. Brass trim. Spring return. Normally closed. Power consumption: holding: 3 W. Power consumption: inrush: 6 VA. Connection: 3/4", PEX expansion union. Maximum working pressure: 150 psi. Medium temperature range: 32–200 °F. Electric supply: 24 V (AC) / (DC). Starting current: ≤ 250 mA. Auxiliary microswitch contact rating (24 V): 5 A. △p max.: 20 psi. Cv: 4.0 gpm.
3D models
Tender text
2-way thermo-electric zone valve Two-way thermo-electric zone valve. Complete with TwisTop™ (code 656354) actuator. Brass trim. Spring return. Normally closed. Power consumption: holding: 3 W. Power consumption: inrush: 6 VA. Connection: 1", press union. Maximum working pressure: 150 psi. Medium temperature range: 32–200 °F. Electric supply: 24 V (AC) / (DC). Starting current: ≤ 250 mA. Auxiliary microswitch contact rating (24 V): 5 A. △p max.: 20 psi. Cv: 4.0 gpm.
3D models
Tender text
2-way thermo-electric zone valve Two-way thermo-electric zone valve. Complete with TwisTop™ (code 656354) actuator. Brass trim. Spring return. Normally closed. Power consumption: holding: 3 W. Power consumption: inrush: 6 VA. Connection: 1", sweat union. Maximum working pressure: 150 psi. Medium temperature range: 32–200 °F. Electric supply: 24 V (AC) / (DC). Starting current: ≤ 250 mA. Auxiliary microswitch contact rating (24 V): 5 A. △p max.: 20 psi. Cv: 4.0 gpm.
3D models
Tender text
2-way thermo-electric zone valve Two-way thermo-electric zone valve. Complete with TwisTop™ (code 656354) actuator. Brass trim. Spring return. Normally closed. Power consumption: holding: 3 W. Power consumption: inrush: 6 VA. Connection: 1", PEX expansion union. Maximum working pressure: 150 psi. Medium temperature range: 32–200 °F. Electric supply: 24 V (AC) / (DC). Starting current: ≤ 250 mA. Auxiliary microswitch contact rating (24 V): 5 A. △p max.: 20 psi. Cv: 4.0 gpm.
3D models
Tender text
2-way thermo-electric zone valve Two-way thermo-electric zone valve. Complete with TwisTop™ (code 656354) actuator. Brass trim. Spring return. Normally closed. Power consumption: holding: 3 W. Power consumption: inrush: 6 VA. Connection: -. Maximum working pressure: 150 psi. Medium temperature range: 32–200 °F. Electric supply: 24 V (AC) / (DC). Starting current: ≤ 250 mA. Auxiliary microswitch contact rating (24 V): 5 A. Cv: 4.3 gpm. Material: brass.
SCIP code
f7f4be19-2f82-4777-b6e5-b89e5417a30f

Applications

Caleffi Rep Locator