Anti-condensation recirculation and distribution unit, with thermostatic control of the return temperature to solid fuel generators.
Product Description
Anti-condensation recirculation and distribution unit, with thermostatic control of the return temperature to solid fuel generators.
By-pass complete closing temperature: Tmin = Tset +10 °C = Tr.
High-efficiency pump: UPM3S Auto 25-60, UPML 25-105.
With insulation.
Technical data
Maximum working pressure:
10 bar
Medium temperature range:
5–100 °C
Maximum percentage of glycol:
50 %
Medium:
glycol solutions, water
Maximum recommended flow rate:
2 m³/h
Material:
brass
Note
The unit should be selected according to the head avalaible at the unit connections, depending on the DN, and not only according to the threaded connections. Given the system head losses, the available head of the unit pump should be evaluated.
Certifications
Drawings and specifications
Part number | Connection | Setting | DN |
---|---|---|---|
281064WYP | G 1" (ISO 228-1) F union |
45 °C | DN 25 (body) |
Type of pump
Para 15-7
|
|||
2D drawings
3D models
Tender text
Anti-condensation recirculation and distribution unit, with thermostatic control of the return temperature to solid fuel generators. With insulation.
By-pass complete closing temperature: Tmin = Tset +10 °C = Tr.
High-efficiency pump: UPM3S Auto 25-60, UPML 25-105. Connection: G 1" (ISO 228-1) F, union. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Setting: 45 °C. Maximum percentage of glycol: 50 %. Medium: glycol solutions, water. Maximum recommended flow rate: 2 m³/h. DN: DN 25 (body). Type of pump: Para 15-7. Material: brass.
SCIP code
40d3c915-c5f6-404c-855d-7ef1c383295e
|
|||
281065WYP | G 1" (ISO 228-1) F union |
55 °C | DN 25 (body) |
Type of pump
Para 15-7
|
|||
3D models
Tender text
Anti-condensation recirculation and distribution unit, with thermostatic control of the return temperature to solid fuel generators. With insulation.
By-pass complete closing temperature: Tmin = Tset +10 °C = Tr.
High-efficiency pump: UPM3S Auto 25-60, UPML 25-105. Connection: G 1" (ISO 228-1) F, union. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Setting: 55 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Maximum recommended flow rate: 2 m³/h. DN: DN 25 (body). Type of pump: Para 15-7. Material: brass.
SCIP code
aa507e1e-a62a-49cf-8394-41cc657b346a
|
|||
281066WYP | G 1" (ISO 228-1) F union |
60 °C | DN 25 (body) |
Type of pump
Para 15-7
|
|||
2D drawings
3D models
Tender text
Anti-condensation recirculation and distribution unit, with thermostatic control of the return temperature to solid fuel generators. With insulation.
By-pass complete closing temperature: Tmin = Tset +10 °C = Tr.
High-efficiency pump: UPM3S Auto 25-60, UPML 25-105. Connection: G 1" (ISO 228-1) F, union. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Setting: 60 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Maximum recommended flow rate: 2 m³/h. DN: DN 25 (body). Type of pump: Para 15-7. Material: brass.
SCIP code
a431bce2-4118-4ace-86d6-a5fa41377c32
|
|||
281067WYP | G 1" (ISO 228-1) F union |
70 °C | DN 25 (body) |
Type of pump
Para 15-7
|
|||
3D models
Tender text
Anti-condensation recirculation and distribution unit, with thermostatic control of the return temperature to solid fuel generators. With insulation.
By-pass complete closing temperature: Tmin = Tset +10 °C = Tr.
High-efficiency pump: UPM3S Auto 25-60, UPML 25-105. Connection: G 1" (ISO 228-1) F, union. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Setting: 70 °C. Maximum percentage of glycol: 50 %. Medium: glycol solutions, water. Maximum recommended flow rate: 2 m³/h. DN: DN 25 (body). Type of pump: Para 15-7. Material: brass.
SCIP code
f70a623a-68c1-4ed5-858a-ae82a9cdd69f
|
|||
281074WYP | G 1 1/4" (ISO 228-1) F union |
45 °C | DN 25 (body) |
Type of pump
Para 15-7
|
|||
2D drawings
3D models
Tender text
Anti-condensation recirculation and distribution unit, with thermostatic control of the return temperature to solid fuel generators. With insulation.
By-pass complete closing temperature: Tmin = Tset +10 °C = Tr.
High-efficiency pump: UPM3S Auto 25-60, UPML 25-105. Connection: G 1 1/4" (ISO 228-1) F, union. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Setting: 45 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Maximum recommended flow rate: 2 m³/h. DN: DN 25 (body). Type of pump: Para 15-7. Material: brass.
SCIP code
00f264ab-8632-490d-96b4-c9f368332071
|
|||
281075WYP | G 1 1/4" (ISO 228-1) F union |
55 °C | DN 25 (body) |
Type of pump
Para 15-7
|
|||
3D models
Tender text
Anti-condensation recirculation and distribution unit, with thermostatic control of the return temperature to solid fuel generators. With insulation.
By-pass complete closing temperature: Tmin = Tset +10 °C = Tr.
High-efficiency pump: UPM3S Auto 25-60, UPML 25-105. Connection: G 1 1/4" (ISO 228-1) F, union. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Setting: 55 °C. Maximum percentage of glycol: 50 %. Medium: glycol solutions, water. Maximum recommended flow rate: 2 m³/h. DN: DN 25 (body). Type of pump: Para 15-7. Material: brass.
SCIP code
52c68fa8-d1d5-4f2d-85af-e0ec231c7034
|
|||
281076WYP | G 1 1/4" (ISO 228-1) F union |
60 °C | DN 25 (body) |
Type of pump
Para 15-7
|
|||
3D models
Tender text
Anti-condensation recirculation and distribution unit, with thermostatic control of the return temperature to solid fuel generators. With insulation.
By-pass complete closing temperature: Tmin = Tset +10 °C = Tr.
High-efficiency pump: UPM3S Auto 25-60, UPML 25-105. Connection: G 1 1/4" (ISO 228-1) F, union. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Setting: 60 °C. Maximum percentage of glycol: 50 %. Medium: glycol solutions, water. Maximum recommended flow rate: 2 m³/h. DN: DN 25 (body). Type of pump: Para 15-7. Material: brass.
SCIP code
c6813a4c-0d5d-4dc6-b989-f6c11e0705f7
|
|||
281077WYP | G 1 1/4" (ISO 228-1) F union |
70 °C | DN 25 (body) |
Type of pump
Para 15-7
|
|||
3D models
Tender text
Anti-condensation recirculation and distribution unit, with thermostatic control of the return temperature to solid fuel generators. With insulation.
By-pass complete closing temperature: Tmin = Tset +10 °C = Tr.
High-efficiency pump: UPM3S Auto 25-60, UPML 25-105. Connection: G 1 1/4" (ISO 228-1) F, union. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Setting: 70 °C. Maximum percentage of glycol: 50 %. Medium: glycol solutions, water. Maximum recommended flow rate: 2 m³/h. DN: DN 25 (body). Type of pump: Para 15-7. Material: brass.
SCIP code
5129dabc-9ad9-46d2-b46e-eb4e718c0efd
|