MixCal™, Adjustable thermostatic mixing valve (sweat)
Product Description
Adjustable thermostatic mixing valve (sweat)
For point of distribution in domestic water systems and radiant hydronic heating systems.
Locking set point knob.
(0 gpm with recirculation).
Technical data
Maximum working pressure:
200 psi
Adjustment temperature range:
85–150 °F
Maximum inlet temperature:
200 °F
Flow rate working range:
1.0-14 gpm, 1.0–14 gpm
Material:
DZR low lead brass
Certifications





Drawings and specifications
Part number | Connection | Note | Cv |
---|---|---|---|
521409A | 1/2" sweat union |
- | 3 |
3D models
Tender text
Adjustable thermostatic mixing valve (sweat)
For point of distribution in domestic water systems and radiant hydronic heating systems.
Locking set point knob. (0 gpm with recirculation). connection: 1/2", sweat union. Maximum working pressure: 200 psi. Adjustment temperature range: 85–150 °F. Maximum inlet temperature: 200 °F. Flow rate working range: 1.0-14 gpm. Cv: 3. Material: DZR low lead brass.
|
|||
521409AC | 1/2" sweat union |
Includes check valves | 3 |
3D models
Tender text
Adjustable thermostatic mixing valve (sweat)
For point of distribution in domestic water systems and radiant hydronic heating systems.
Locking set point knob. (0 gpm with recirculation). connection: 1/2", sweat union. Maximum working pressure: 200 psi. Adjustment temperature range: 85–150 °F. Maximum inlet temperature: 200 °F. Flow rate working range: 1.0-14 gpm. Cv: 3. Material: DZR low lead brass.
|
|||
521509A | 3/4" sweat union |
- | 3 |
3D models
Tender text
Adjustable thermostatic mixing valve (sweat)
For point of distribution in domestic water systems and radiant hydronic heating systems.
Locking set point knob. (0 gpm with recirculation). connection: 3/4", sweat union. Maximum working pressure: 200 psi. Adjustment temperature range: 85–150 °F. Maximum inlet temperature: 200 °F. Flow rate working range: 1.0-14 gpm. Cv: 3. Material: DZR low lead brass.
|
|||
521509AC | G 1" A (ISO 228-1) M sweat union |
Includes check valves | 3 |
3D models
Tender text
Adjustable thermostatic mixing valve (sweat)
For point of distribution in domestic water systems and radiant hydronic heating systems.
Locking set point knob. (0 gpm with recirculation). connection: G 1" A (ISO 228-1) M, sweat union. Maximum working pressure: 200 psi. Adjustment temperature range: 85–150 °F. Maximum inlet temperature: 200 °F. Flow rate working range: 1.0–14 gpm. Cv: 3. Material: DZR low lead brass.
|
|||
521609A | 1" sweat union |
- | 3 |
3D models
Tender text
Adjustable thermostatic mixing valve (sweat)
For point of distribution in domestic water systems and radiant hydronic heating systems.
Locking set point knob. (0 gpm with recirculation). connection: 1", sweat union. Maximum working pressure: 200 psi. Adjustment temperature range: 85–150 °F. Maximum inlet temperature: 200 °F. Flow rate working range: 1.0-14 gpm. Cv: 3. Material: DZR low lead brass.
|
|||
521609AC | 1" sweat union |
Includes check valves | 3 |
3D models
Tender text
Adjustable thermostatic mixing valve (sweat)
For point of distribution in domestic water systems and radiant hydronic heating systems.
Locking set point knob. (0 gpm with recirculation). connection: 1", sweat union. Maximum working pressure: 200 psi. Adjustment temperature range: 85–150 °F. Maximum inlet temperature: 200 °F. Flow rate working range: 1.0-14 gpm. Cv: 3. Material: DZR low lead brass.
|
|||
521610A | 1" MNPT union |
- | 3 |
3D models
Tender text
Adjustable thermostatic mixing valve (sweat)
For point of distribution in domestic water systems and radiant hydronic heating systems.
Locking set point knob. (0 gpm with recirculation). connection: 1" MNPT, union. Maximum working pressure: 200 psi. Adjustment temperature range: 85–150 °F. Maximum inlet temperature: 200 °F. Flow rate working range: 1.0-14 gpm. Cv: 3. Material: DZR low lead brass.
|
|||
521610AC | 1" MNPT union |
Includes check valves | 3 |
3D models
Tender text
Adjustable thermostatic mixing valve (sweat)
For point of distribution in domestic water systems and radiant hydronic heating systems.
Locking set point knob. (0 gpm with recirculation). connection: 1" MNPT, union. Maximum working pressure: 200 psi. Adjustment temperature range: 85–150 °F. Maximum inlet temperature: 200 °F. Flow rate working range: 1.0-14 gpm. Cv: 3. Material: DZR low lead brass.
|