Z1 actuator for motorized zone valves (closed)
Product Description
Z1 actuator for motorized zone valves (closed)
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251.
Normally closed actuator for motorized zone valves.
Z1 Normally closed actuators fit on Z2 and Z3 valves. Normally open actuators fit on Z2 valves only.
Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector.
Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V).
Conduit connector size:1/2".
With auxiliary microswitch.
Technical data
Power consumption at full capacity:
7 VA
Download
Drawings and specifications
Code | Note | Electric supply | |
---|---|---|---|
Z111000 | Micro-switch, 18" wires | 24 V (AC) | |
3D models
Tender text
Z1 actuator for motorized zone valves (closed)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator for motorized zone valves.
Z1 Normally closed actuators fit on Z2 and Z3 valves. Normally open actuators fit on Z2 valves only. Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector. Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V). Conduit connector size:1/2". Electric supply: 24 V (AC). Power consumption at full capacity: 7 VA.
|
|||
Z111900 | High current switch, 18" wires | 24 V (AC) | |
3D models
Tender text
Z1 actuator for motorized zone valves (closed)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator for motorized zone valves.
Z1 Normally closed actuators fit on Z2 and Z3 valves. Normally open actuators fit on Z2 valves only. Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector. Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V). Conduit connector size:1/2". Electric supply: 24 V (AC). Power consumption at full capacity: 7 VA.
|
|||
Z116000 | Micro-switch, 6" wires | 120 V (AC) | |
3D models
Tender text
Z1 actuator for motorized zone valves (closed)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator for motorized zone valves.
Z1 Normally closed actuators fit on Z2 and Z3 valves. Normally open actuators fit on Z2 valves only. Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector. Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V). Conduit connector size:1/2". Electric supply: 120 V (AC). Power consumption at full capacity: 7 VA.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
Z151000 | Micro-switch, terminal blocks | 24 V (AC) | |
3D models
Tender text
Z1 actuator for motorized zone valves (closed)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator for motorized zone valves.
Z1 Normally closed actuators fit on Z2 and Z3 valves. Normally open actuators fit on Z2 valves only. Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector. Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V). Conduit connector size:1/2". Electric supply: 24 V (AC). Power consumption at full capacity: 7 VA.
|
|||
Z161000 | Terminal blocks | 24 V (AC) | |
3D models
Tender text
Z1 actuator for motorized zone valves (closed)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator for motorized zone valves.
Z1 Normally closed actuators fit on Z2 and Z3 valves. Normally open actuators fit on Z2 valves only. Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector. Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V). Conduit connector size:1/2". Electric supply: 24 V (AC). Power consumption at full capacity: 7 VA.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
Z121000 | 18" wires | 24 V (AC) | |
3D models
Tender text
Z1 actuator for motorized zone valves (closed)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator for motorized zone valves.
Z1 Normally closed actuators fit on Z2 and Z3 valves. Normally open actuators fit on Z2 valves only. Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector. Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V). Conduit connector size:1/2". Electric supply: 24 V (AC). Power consumption at full capacity: 7 VA.
|
|||
Z126000 | 6" wires | 120 V (AC) | |
3D models
Tender text
Z1 actuator for motorized zone valves (closed)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251. Normally closed actuator for motorized zone valves.
Z1 Normally closed actuators fit on Z2 and Z3 valves. Normally open actuators fit on Z2 valves only. Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector. Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V). Conduit connector size:1/2". Electric supply: 120 V (AC). Power consumption at full capacity: 7 VA.
|